{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1316-2AK60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1316-2AK60","canonicalUrl":"https://aoctrl.com/siemens/3RT1316-2AK60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1316-2AK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 4 NO main contacts, spring-loaded terminals, 4 kW at 400 V AC-2, 45 mm width, active production.","salesMarkdown":"## SIRIUS 3RT1316-2AK60 — 4 NO Power Contactor, Size S00 It is rated for 4 kW at 400 V in AC-2 duty (slip-ring motor switching) and handles up to 10 A in AC-12 resistive loads. The 4 NO configuration means this contactor switches four separate power circuits simultaneously; there are no NC auxiliary contacts built in, so if you need a feedback signal to a PLC, you'll add a separate auxiliary contact block on the side. Spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). That's a standard control-panel range — fine for motor leads up to 4 kW. Pollution degree 3 (conductive pollution) is assumed, so the contactor is suited for industrial enclosures where some dust and condensation are present.","metaTitle":"Siemens 3RT1316-2AK60 SIRIUS Power Contactor, 4 NO, 4 kW AC-","metaDescription":"Siemens 3RT1316-2AK60 SIRIUS power contactor, Size S00, 4 NO main contacts, 4 kW at 400 V AC-2, spring-loaded terminals, active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 60 Hz rated value":"120 V","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"4","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"4","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=500946&mlfb=3RT1316-2AK60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1316-2AK60/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1316-2AK60?","answer":"The depth is 72 mm, which fits standard 200 mm deep enclosures with room for wiring."},{"question":"What wire size does the spring terminal accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG)."},{"question":"Will 3RT1316-2AK60 drop into a panel specified for 3RT1016-2AP02?","answer":"Both are Size S00 contactors on the same 45 mm DIN-rail footprint, so the mechanical fit is the same. The 3RT1316-2AK60 has 4 NO main contacts and spring terminals; the 3RT1016-2AP02 has a different contact configuration and screw terminals. Check your wiring diagram for contact count and terminal type before swapping."},{"question":"Where can I buy 3RT1316-2AK60?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1316-2AK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1316-2AK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}