{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1316-2AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1316-2AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT1316-2AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1316-2AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S00, 4 NO main contacts, 10 A AC-12, spring-loaded terminals, 45 mm width, screw and snap-on mounting.","salesMarkdown":"It uses spring-loaded terminals for the main current circuit, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14) AWG. Rated for AC-12 duty at 10 A maximum operating current, it handles resistive loads in control circuits. For motor loads under AC-2 duty at 400 V, it is rated for 4 kW — that covers small pumps, fans, and compressors in light-to-moderate starting duty. The coil is rated for 220 V at 50 Hz and 240 V at 60 Hz, with an operating range of 0.85 to 1.1 at 50 Hz, and 0.8 to 1.1 at 60 Hz. Side-by-side mounting is allowed with zero side clearance — no derating needed for adjacent units. ## Switching capability and coordination DC switching ratings cover common control voltages: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. AC switching at 230 V is rated 6 A, and at 400 V it is 3 A — these are the resistive/inductive loads the contacts can break without excessive wear. Type 1 (contactor may need replacement) allows a 35 A fuse. This matters for selectivity studies — if upstream protection is already set at 35 A, you are limited to Type 1 coordination. ## Environmental limits","metaTitle":"Siemens 3RT1316-2AP60 SIRIUS Power Contactor, 4NO, 10A AC-12","metaDescription":"Siemens SIRIUS 3RT1316-2AP60 power contactor, size S00, 4 NO main contacts, 10 A AC-12, spring-loaded terminals, 45 mm width. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 60 Hz rated value":"240 V","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"4","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"4","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=68354&mlfb=3RT1316-2AP60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1316-2AP60/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RT1316-2AP60?","answer":"The 3RT1016-2AP02 is a size S00 contactor from the same SIRIUS family, but it uses screw terminals instead of spring-loaded terminals. The 3RT1316-2AP60 also has a higher AC-12 current rating (10 A vs the 3RT1016-2AP02's lower rating) and a wider coil voltage tolerance range. Panel cutouts are the same 45 mm width, so it drops into the same DIN-rail footprint without rewiring the mounting, but the terminal type difference means the wiring method changes."},{"question":"What is 3RT1316-2AP60's listed depth?","answer":"The depth is 72 mm."},{"question":"What wire sizes does the spring-loaded terminal accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14) AWG."},{"question":"Will 3RT1316-2AP60 drop into a panel specified around 3RT1016-2AP02 without rewiring?","answer":"Yes on the mounting — both are 45 mm wide size S00 contactors that snap onto 35 mm DIN rail. No on the wiring — the 3RT1316-2AP60 uses spring-loaded terminals, while the 3RT1016-2AP02 uses screw terminals, so the termination method is different. The panel layout and footprint are identical."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1316-2AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1316-2AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}