{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1317-2AN60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1317-2AN60","canonicalUrl":"https://aoctrl.com/siemens/3RT1317-2AN60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1317-2AN60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1317-2AN60 power contactor, size S00, 4 NO main contacts, 5.5 kW at AC-2 400 V, spring-loaded terminals, 45 mm width, current production.","salesMarkdown":"## What it is and what it does The Siemens SIRIUS 3RT1317-2AN60 is a power contactor in size S00, designed for switching motor loads in control panels. It carries 4 normally-open main contacts and is rated for 5.5 kW at AC-2 duty at 400 V, meaning it handles moderate motor loads like pumps or conveyors without excessive contact wear. The main circuit uses spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or stranded wire — no screw torque check needed, which speeds panel wiring and reduces loose-connection callbacks. ## Mounting and integration Mounts via screw or snap-on onto a 35 mm standard mounting rail per DIN EN 50022. At 45 mm wide, it fits a standard DIN-rail footprint; side-by-side mounting is allowed, so you can gang multiple contactors without extra spacing. Front and terminal protection is IP20 — safe for finger contact inside an enclosure but not for washdown areas. Operating temperature range is -25 to +60 °C, which covers most indoor panel environments.","metaTitle":"Siemens SIRIUS 3RT1317-2AN60 Power Contactor, S00, 4 NO, 5.5","metaDescription":"Siemens SIRIUS 3RT1317-2AN60 power contactor, size S00, 4 NO main contacts, 5.5 kW at AC-2 400 V, spring-loaded terminals, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 V","at 60 Hz rated value":"200 ... 220 V","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"5.5 kW","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"4","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"4","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=265822&mlfb=3RT1317-2AN60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1317-2AN60/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a size S00 power contactor with 4 NO main contacts, rated 5.5 kW at AC-2 400 V, and a maximum operating current of 10 A at AC-12. The coil is rated for 50/60 Hz at 200 V (50 Hz) or 200–220 V (60 Hz)."},{"question":"What type of terminals does it use?","answer":"Spring-loaded terminals on the main circuit, accepting 2x (0.25... 2.5 mm²) solid or stranded wire, or 2x (24... 14) AWG."},{"question":"Will 3RT1317-2AN60 drop into a panel that was specified around 3RT1016-2AP02 without rewiring?","answer":"Both are size S00 contactors on a 45 mm DIN-rail footprint, so the mechanical fit and rail mounting are identical. However, verify the coil voltage and auxiliary contact configuration — 3RT1317-2AN60 has 4 NO main contacts and no NC, while the peer may differ. Terminal type (spring-loaded here) matches if the peer also uses spring terminals; if the peer uses screw terminals, the wiring method changes."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1317-2AN60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1317-2AN60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}