{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1336-1AK60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1336-1AK60","canonicalUrl":"https://aoctrl.com/siemens/3RT1336-1AK60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1336-1AK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1336-1AK60, Size S2, 23 kW at 230 V (60 °C), screw-type terminals, DIN rail mount.","salesMarkdown":"The 3RT1336-1AK60: The 23 kW at 230 V (60 °C) rating is the motor-switching capacity under a standard 230 V three-phase supply at elevated ambient temperature — the rating that governs most European panel designs. The AC-2 rating of 11 kW at 400 V covers slip-ring motor loads where starting current is moderate. Insulation voltage of 690 V means the contactor can be used in 400/690 V systems without derating the internal creepage distances. The contactor carries a mechanical life of 10,000,000 cycles typical, and a maximum switching rate of 1,000 operations per hour at AC-1. The auxiliary contact block is rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — these are the values to check when coordinating with a PLC output or a control relay. Main current circuit connections use screw-type terminals. The minimum permissible cross-section at 40 °C and 60 °C is 16 mm² for the main circuit.","metaTitle":"Siemens 3RT1336-1AK60 SIRIUS Power Contactor, 23 kW at 230 V","metaDescription":"Siemens SIRIUS 3RT1336-1AK60 power contactor, Size S2. Rated 23 kW at 230 V (60 °C), 11 kW at AC-2 400 V. Screw terminals, DIN rail mount. Active lifecycle. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"73 mm","at AC":"10 ... 30 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 60 Hz rated value":"120 V","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"11 kW","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"23 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=274836&mlfb=3RT1336-1AK60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1336-1AK60/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"It is rated for 23 kW at 230 V at 60 °C and 11 kW at AC-2 duty at 400 V. The insulation voltage is 690 V."},{"question":"What wire sizes does the 3RT1336-1AK60 accept?","answer":"Screw terminals accept solid: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), max 2x (0.75...4 mm²). Stranded: 2x (0.75...25 mm²). Minimum main circuit cross-section is 16 mm² at 40 °C and 60 °C."},{"question":"What is the mounting method for this contactor?","answer":"Screw or snap-on mounting onto a 35 mm standard mounting rail per DIN EN 50022. Side-by-side mounting is permitted."},{"question":"What compliance documentation is available?","answer":"The part is RoHS compliant with a substance prohibition date of 05/01/2012. Standard Siemens SIRIUS documentation includes CE, UL, and CSA declarations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1336-1AK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1336-1AK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}