{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1456-6AP36-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1456-6AP36-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1456-6AP36-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1456-6AP36-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, contactor, 3RT1456-6AP36-ZX95, size S6, 220-240 V AC/DC coil, screw-type coil terminals, 4 auxiliary contacts, screw fixing, 172 x 120 x 170 mm.","salesMarkdown":"## SIRIUS S6 Contactor — 220-240 V AC/DC Coil, 4 Auxiliaries The Siemens 3RT1456-6AP36-ZX95 is a SIRIUS-branded contactor in frame size S6, designed for motor switching and general load control in industrial panels. Its coil accepts 220-240 V AC or DC, with a pickup threshold of 0.8 × rated voltage and a dropout floor of 0.8 × rated (0.8 to 1.1 at 60 Hz). Opening delay runs 40-60 ms on both AC and DC; arcing time is 10-15 ms. The contactor carries four built-in auxiliary contacts (attachable count: 4), each rated for switching at 24 V (10 A), 48 V (2 A), 60 V (2 A), 110 V (1 A), 125 V (0.9 A), 220 V (0.3 A), and 230 V (6 A). Mounts via screw fixing (two 9 mm holes) on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Overall dimensions: 172 mm height, 120 mm width, 170 mm depth. The main power circuit accepts stranded conductors 25-120 mm²; auxiliary terminals accept solid or stranded 0.5-1.5 mm² (2×) or 0.75-2.5 mm² (2×), max 2× 0.75-4 mm². Coil terminals are screw-type.","metaTitle":"Siemens 3RT1456-6AP36-ZX95 SIRIUS S6 Contactor, 220-240V AC/","metaDescription":"Siemens 3RT1456-6AP36-ZX95 SIRIUS contactor, size S6, 220-240V AC/DC coil, 4 built-in auxiliary contacts. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"120 mm","at AC":"40 ... 60 ms","at DC":"40 ... 60 ms","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"25 ... 120 mm²","at 50 Hz":"0.8","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"9 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 ... 240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"17 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"3 mm","at AC in hot operating state":"86.4 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 350 A (690 V, 100 kA)","Without Load Current Share Typical":"5.2 W","closing power of magnet coil at DC":"360 W","holding power of magnet coil at DC":"5.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"28.8 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"140 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/349680e891cc337072a780386b39ed3f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=497565&mlfb=3RT1456-6AP36-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1456-6AP36-ZX95/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3RT1456-6AP36-ZX95?","answer":"Submit an RFQ through this listing. The part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation is available for 3RT1456-6AP36-ZX95?","answer":"As a SIRIUS-branded Siemens component, it carries CE marking and is manufactured under IEC/EN 60947-4-1. RoHS and REACH declarations of conformity are standard from Siemens for this product series. UL and CSA listings are typical for the SIRIUS contactor family, though specific certification marks should be confirmed from the nameplate or declaration of conformity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1456-6AP36-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1456-6AP36-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}