{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1466-6AF36-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1466-6AF36-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1466-6AF36-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1466-6AF36-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1466-6AF36-ZX95, size S10 contactor, 4-pole, 110-127 V AC/DC coil, screw-type terminals, auxiliary switch, 145 x 202 x 210 mm.","salesMarkdown":"## Contactor for High-Current Motor and Resistive Loads It accepts main conductor cross-sections up to 240 mm² stranded, so it handles the incoming power feed for large drives or distribution points without needing an additional terminal block. The screw-type coil terminals and screw fixing to the mounting surface are standard for panel builders who prefer positive retention over clip-on rails. The S10 frame size tells you this contactor occupies a specific footprint — 145 mm wide, 202 mm deep, 210 mm tall — and its mechanical endurance of 10 million operations means it is rated for frequent cycling in applications like conveyor start/stop or compressor cycling. The coil operates on AC or DC from 110 to 127 V, so it can be driven from a common control transformer or a 125 VDC battery-backed supply without a separate rectifier. Auxiliary contact ratings drop with voltage: 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V — the lower current at higher voltage reflects the switching arc limitation, so verify the pilot load against these curves rather than assuming a single ampacity. Mounting is by screw fixing, not DIN rail, so plan for drilled holes in the backplate. Operating temperature range is -25 to +60 °C, with storage from -55 to +80 °C, so it survives transport in cold climates but needs derating if the panel ambient exceeds 60 °C.","metaTitle":"Siemens SIRIUS 3RT1466-6AF36-ZX95 Contactor, S10, 110-127V A","metaDescription":"Siemens SIRIUS 3RT1466-6AF36-ZX95 contactor, size S10, 110-127 V AC/DC coil, screw terminals, 4-pole, auxiliary switch included. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"110 ... 127 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 ... 127 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"105.6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 500 A (690 V, 100 kA)","Without Load Current Share Typical":"7.4 W","closing power of magnet coil at DC":"650 W","holding power of magnet coil at DC":"7.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"240 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcd3aad2e48b02d9ddda6447d1675b18.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=168597&mlfb=3RT1466-6AF36-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1466-6AF36-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What are the main dimensions of this contactor?","answer":"Width is 145 mm, depth is 202 mm, and height is 210 mm. These are the body dimensions excluding terminal projections."},{"question":"What conductor sizes does the main power path accept?","answer":"The main terminals accept stranded conductors from 70 to 240 mm². The auxiliary/coil terminals accept solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²)."},{"question":"Does this contactor include an auxiliary contact block?","answer":"Yes, an auxiliary switch is integrated on the base device. No separate add-on block is required for basic N.O./N.C. feedback."},{"question":"What coil voltage options does this part have?","answer":"The coil is rated for 110-127 V and accepts both AC and DC supply. This covers common 110 VAC control transformers and 125 VDC battery systems."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1466-6AF36-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1466-6AF36-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}