{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1466-6AP36-ZI41","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1466-6AP36-ZI41","canonicalUrl":"https://aoctrl.com/siemens/3RT1466-6AP36-ZI41","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1466-6AP36-ZI41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, Size S10, order code 3RT1466-6AP36-ZI41, 220-240 V AC/DC coil, 70-240 mm² power circuit.","salesMarkdown":"Its 220-240 V AC/DC coil means you can wire it into either an AC or DC control circuit without swapping the magnet assembly; the coil draws from a single rated supply range regardless of supply type. The power circuit accepts stranded conductors from 70 mm² up to 240 mm², so it ties directly into heavy-gauge motor feeders or busbars without an intermediate terminal block. The AC-1 maximum operating rate of 600 operations per hour means this contactor can handle resistive loads (heating, lighting) at a steady cadence — useful for oven or furnace control where the contactor cycles every few seconds. For DC switching, the ratings drop significantly because DC arcs are harder to extinguish: at 24 V it's rated 10 A, at 48 V it drops to 2 A, and at 220 V it's only 0.3 A. The operate time of 40 to 80 ms (both AC and DC) is the delay from coil energization to main contact closure; factor that into your safety circuit timing if the contactor is part of a guard-monitoring chain. Mounting is by screw fixing (not DIN rail), so plan for four bolts into a backplate. The enclosure protection is IP00 on the body; with the supplied cover or box terminal the front face reaches IP20 — finger-safe but not washdown-rated. That's enough for air circulation and arc flash containment in a standard panel layout.","metaTitle":"Siemens 3RT1466-6AP36-ZI41 SIRIUS Contactor, Size S10, 220-2","metaDescription":"Siemens SIRIUS 3RT1466-6AP36-ZI41 contactor, Size S10, 220-240 V AC/DC coil, 70-240 mm² power circuit. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","title":"3RT1466-6AP36-ZI41","Height":"210 mm","Maximum":"2 000 m","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","description":"CONTACTOR, 400A/AC-1 AC(40...60HZ)/DC OPERATION UC 220-240V AUXILIARY CONTACTS 2NO+2NC 3-POLE, SIZE S10 BAR CONNECTIONS CONVENT. OPERATING MECHANISM","On The Front":"IP00; IP20 on the front with cover / box terminal","Initial Value":"0.8","Mounting type":"screw fixing","Of Magnet Coil":"Screw-type terminals","Of The Terminal":"IP00","Type of voltage":"AC/DC","at AC-1 maximum":"600 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","Full-scale value":"1.1","Size of contactor":"S10","Product brand name":"SIRIUS","Product designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 ... 240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"Connection bar","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Of Main Circuit Rated Value":"8 kV","at maximum AC-1 rated value":"240 mm²","Design of the surge suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","Function Module For Communication":"No","Closing power of magnet coil at DC":"650 W","Holding power of magnet coil at DC":"7.4 W","Operating current at AC-12 maximum":"10 A","Relative humidity during operation":"0 ... 95 %","With Type Of Assignment 2 Required":"gR: 500 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","Protection against electrical shock":"finger-safe when touched vertically from front acc. to IEC 60529","at AWG conductors for main contacts":"2/0 ... 500 kcmil","Mirror contact acc. to IEC 60947-4-1":"Yes","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","Reference code acc. to DIN EN 81346-2":"Q","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","Type of voltage for main current circuit":"AC","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","Product function Short circuit protection":"No","Number of NC contacts for auxiliary contacts":"2","Number of NO contacts for auxiliary contacts":"2","Type of voltage of the control supply voltage":"AC/DC","positively driven operation acc. to IEC 60947-5-1":"No","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcd3aad2e48b02d9ddda6447d1675b18.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=359074&mlfb=3RT1466-6AP36-ZI41"},"ai":{"faq":[{"question":"What is the depth of this contactor?","answer":"The depth is 202 mm. Combined with the width of 145 mm and height of 210 mm, it requires a panel cutout or mounting area of at least those dimensions plus the clearance distances (10 mm up/down/side, 20 mm front)."},{"question":"What wire sizes does the power circuit accept?","answer":"For solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). For stranded conductors: 70 to 240 mm². The auxiliary and coil terminals are screw-type."},{"question":"What compliance documentation is available?","answer":"As a Siemens SIRIUS product, it carries CE marking for the European market. RoHS and REACH declarations are standard for this brand. UL and CSA listings are typical for the SIRIUS contactor family, though specific certification marks should be verified against the nameplate on the unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1466-6AP36-ZI41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1466-6AP36-ZI41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}