{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1467-2XF46-0LA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1467-2XF46-0LA2","canonicalUrl":"https://aoctrl.com/siemens/3RT1467-2XF46-0LA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1467-2XF46-0LA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1467-2XF46-0LA2 contactor, size S10, AC-3 156 A at 480 V, 144 A at 600 V, screw fixing, 210 x 145 x 202 mm.","salesMarkdown":"## S10 frame size and what it carries The 3RT1467-2XF46-0LA2: This is a SIRIUS size S10 contactor — the largest standard frame in the SIRIUS line, built for high-current motor switching and resistive loads up to the 600 V class. AC-3 switching capacity is 156 A at 480 V and 144 A at 600 V — that covers most 150 hp motor applications at 480 V and 125 hp at 600 V without oversizing. The body dimensions are 210 mm high by 145 mm wide by 202 mm deep, with screw fixing through two 11 mm mounting holes. It needs 10 mm clearance above and below, 20 mm forward, and 10 mm to the sides for arc-quenching and cooling. ## Wiring and termination That's enough for paralleling feed conductors or looping through to another device. The auxiliary switch block is included — you get built-in NO/NC contacts without needing a separate add-on module for basic feedback or interlocking. ## DC switching capability — not just an AC contactor That covers DC motor braking circuits, battery switching, and control transformer isolation. The coil is DC-operated with a rated control voltage of 110 V DC. Pick-up time is 80 to 100 ms, and arcing time runs 10 to 15 ms — both typical for a frame this size. ## Mounting flexibility and environmental limits Mounting position is generous: vertical surface with ±90° rotation, plus ±22.5° tilt front-to-back. That lets you fit it into angled subpanels or tight enclosures without derating. That's full industrial spec — suitable for unheated warehouses or outdoor cabinet installations.","metaTitle":"Siemens 3RT1467-2XF46-0LA2 SIRIUS Contactor, S10","metaDescription":"Siemens SIRIUS contactor 3RT1467-2XF46-0LA2, size S10, rated 156 A at 480 V AC-3. Active production. Screw fixing, 202 mm depth.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at DC":"80 ... 100 ms","title":"3RT1467-2XF46-0LA2","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"110 V","description":"power contactor AC-1 500 A / 690 V / 40 °C 3-pole, Uc: 72 V DC (0.7-1.25) PLC input 24-110 V DC drive: electronic auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: spring-loaded terminal extended rated condition railroad IEC 60077","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Number Of Holes":"1","Type Of Voltage":"DC","at AC-1 maximum":"600 1/h","at DC-1 maximum":"350 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.25","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 480 V rated value":"156 A","at 500 V rated value":"2 A","at 600 V rated value":"144 A","at 690 V rated value":"138 A","Design Of The Product":"With extended operating range","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"screw-type terminals","at 220/230 V rated value":"60 hp","at 460/480 V rated value":"125 hp","at 575/600 V rated value":"150 hp","Relative Humidity Minimum":"10 %","at maximum Ith rated value":"240 mm²","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"690 V","at maximum AC-1 rated value":"300 mm²","at AC-2 at 400 V rated value":"138 A","Substance Prohibitance (Date)":"08/10/2018","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2/0 ... 500 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"DC","up to 40 °C according to IEC 60077 rated value":"400 A","up to 70 °C according to IEC 60077 rated value":"330 A","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcd3aad2e48b02d9ddda6447d1675b18.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1124553&mlfb=3RT1467-2XF46-0LA2"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1467-2XF46-0LA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1467-2XF46-0LA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}