{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1467-6PP35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1467-6PP35","canonicalUrl":"https://aoctrl.com/siemens/3RT1467-6PP35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1467-6PP35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S10 contactor, 3RT1467-6PP35, 200-277 V AC/DC coil, screw-type terminals, 70-240 mm² stranded cable, 210 x 165 x 202 mm.","salesMarkdown":"## Siemens 3RT1467-6PP35 SIRIUS Contactor, S10 Frame It lands in the middle of the SIRIUS lineup — bigger than the S6 or S0 frames, smaller than the S12, and sized for applications that need the 70-240 mm² stranded cable range and the 200-277 V AC/DC coil. The coil accepts both AC and DC at 200-277 V, with a pickup dropout ratio that holds in at 80% of rated voltage and drops out at 0.8 times the initial value. That wide tolerance means it stays latched through a saggy line or a weak generator start — useful on a motor control center fed from a transformer that's already loaded. Mounting is screw-fixed to a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. That's not a DIN-rail clip — plan for panel drilling. The contactor sits 210 mm tall, 165 mm wide, 202 mm deep, so leave room in the enclosure for the arc chutes and the cable bend radius on the 240 mm² tails. The 70-240 mm² stranded termination is the headline here — that's a heavy cable range, typical for a 300+ A motor circuit or a feeder tap. The screw-type coil terminals accept 2x 0.5-1.5 mm² solid or 2x 0.75-2.5 mm² stranded, max 2x 0.75-4 mm². That's enough for a 1.5 mm² control wire from a PLC output or a relay, but if you're paralleling two 4 mm² feeds for the coil, you're at the limit. Arcing time runs 10-15 ms, and the dropout delay is 80-100 ms on both AC and DC. That's fast enough for basic motor protection coordination, but if you're sequencing contactors for a reversing starter or a wye-delta transition, you'll want to check the overlap against your PLC scan cycle. If your panel was built around a 3RT1264-6AP36-0KA1 or a 3RT1076-6AP36, those are different frame sizes and coil voltages — the S10 is physically larger and the coil range is different, so don't assume a drop-in swap without checking the mounting hole pattern and the cable lug clearance.","metaTitle":"Siemens 3RT1467-6PP35 SIRIUS Contactor, S10 Size, 200-277 V","metaDescription":"Siemens SIRIUS contactor 3RT1467-6PP35, size S10, coil 200-277 V AC/DC. Rated for 70-240 mm² stranded cable. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"165 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.5","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"105.6 W","Substance Prohibitance (Date)":"08/10/2018","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 500 A (690 V, 100 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","type of PLC-control input according to IEC 60947-1":"Type 2","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"300 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcd3aad2e48b02d9ddda6447d1675b18.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1124560&mlfb=3RT1467-6PP35","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1467-6PP35/alternatives.json"},"ai":{"faq":[{"question":"Will 3RT1467-6PP35 drop into a panel designed for 3RT1264-6AP36-0KA1?","answer":"No, the S10 frame (3RT1467) is physically larger than the S0 or S2 frames used on the 3RT1264 series. The mounting hole pattern, cable lug clearance, and overall dimensions are different — verify the panel cutout and bus bar spacing before ordering."},{"question":"What is the operating temperature range for this contactor?","answer":"It operates from -25 to +60 °C and can be stored from -55 to +80 °C. The +60 °C limit is the hard ceiling for the coil and arc chamber."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1467-6PP35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1467-6PP35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}