{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1467-6SP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1467-6SP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1467-6SP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1467-6SP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S10 contactor, 3RT1467-6SP36, screw-type coil terminals, 200-277 V AC/DC coil, 240 mm² stranded main circuit, MTBF 75 a.","salesMarkdown":"## SIRIUS S10 Contactor — 3RT1467-6SP36 The Siemens 3RT1467-6SP36 is a SIRIUS S10-frame contactor rated for motor switching and power distribution in industrial control panels. It carries a 200-277 V AC/DC coil with screw-type terminals, and the main circuit accepts stranded conductors up to 240 mm² — sized for high-current motor feeders or transformer primary switching. Fastening is via screw fixing through an 11 mm hole. ## Coil and Switching Characteristics The AC/DC coil operates across 200-277 V rated value, with a pickup threshold of 0.8 x rated and a dropout of 0.5 at 50 Hz / 0.8-1.1 at 60 Hz. Auxiliary contacts are present, rated at 24 V 10 A, 48 V 2 A, 60 V 2 A, 110 V 1 A, 125 V 0.9 A, and 220 V 0.3 A (-). These support control-circuit interlocking or status feedback without an add-on block. Dimensions: 210 mm height, 145 mm width, 202 mm depth. The S10 frame size is the largest in the SIRIUS contactor family, so verify enclosure depth before specifying. Terminal capacity on the control circuit: solid conductors 2x (0.5-1.5 mm²) and 2x (0.75-2.5 mm²), max 2x (0.75-4 mm²). The main circuit accepts stranded 70-240 mm² — suitable for large-gauge power wiring common in 200+ A motor feeders.","metaTitle":"Siemens 3RT1467-6SP36 SIRIUS S10 Contactor, 200-277V AC/DC C","metaDescription":"Siemens SIRIUS S10 contactor 3RT1467-6SP36, 200-277V AC/DC coil, MTBF 75 a, 240 mm² stranded terminals. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"MTBF":"75 a","Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"115 ... 130 ms","at DC":"115 ... 130 ms","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.5","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"105.6 W","Substance Prohibitance (Date)":"08/10/2018","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 500 A (690 V, 100 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"200 1/h","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","category according to EN ISO 13849-1":"2","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","stop category according to EN 60204-1":"0","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","safety device type according to IEC 61508-2":"Type B","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","PFHD with high demand rate according to EN 62061":"4.5E-7 1/h","SIL Claim Limit (subsystem) according to EN 62061":"2","PFDavg with low demand rate according to IEC 61508":"0.007","performance level (PL) according to EN ISO 13849-1":"c","type of PLC-control input according to IEC 60947-1":"Type 1","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"300 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcd3aad2e48b02d9ddda6447d1675b18.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1124563&mlfb=3RT1467-6SP36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1467-6SP36/alternatives.json"},"ai":{"faq":[{"question":"What is the MTBF of 3RT1467-6SP36?","answer":"The listed MTBF is 75 a, indicating a mean time between failures of 75 years under stated operating conditions — a strong reliability figure for a power contactor used in continuous-duty applications."},{"question":"What are the key dimensions and mounting requirements?","answer":"Dimensions are 210 mm height, 145 mm width, 202 mm depth. Mounting requires 10 mm clearance upwards, 10 mm downwards, 20 mm forwards, and 10 mm at the side. Fastening is via screw fixing through an 11 mm hole."},{"question":"Where can I buy 3RT1467-6SP36 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment."},{"question":"What compliance documentation is available for 3RT1467-6SP36?","answer":"As a Siemens SIRIUS product, standard compliance documentation including CE declaration of conformity, RoHS, and REACH is typically provided with the shipment. Specific UL or IEC certification details should be confirmed at quote time against the buyer's jurisdiction requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1467-6SP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1467-6SP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}