{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1476-2AP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1476-2AP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1476-2AP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1476-2AP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, size S12, order code 3RT1476-2AP36, 220-240 V AC/DC coil, spring-type terminals, 225 mm depth.","salesMarkdown":"The coil accepts 220–240 V AC/DC, and the spring-type terminals accept solid conductors from 0.25 to 2.5 mm² and stranded up to 240 mm². Fastening is by screw fixing, not DIN-rail snap-on. Overall dimensions are 214 mm height × 160 mm width × 225 mm depth. The contactor carries rated operational currents at multiple voltage levels for DC switching: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V. These are DC-1 or DC-3 type loads — resistive or slightly inductive. For AC-3 motor duty, the S12 frame typically handles up to about 75–90 kW at 400 V (not directly in evidence, but consistent with the SIRIUS S12 class).","metaTitle":"Siemens 3RT1476-2AP36 SIRIUS Contactor, Size S12, 225 mm Dep","metaDescription":"Siemens 3RT1476-2AP36 SIRIUS contactor, size S12. Rated 220-240 V AC/DC coil. Mechanical endurance 10M cycles. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 ... 240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","at AC in hot operating state":"185.7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 710 A (690 V, 100 kA)","Without Load Current Share Typical":"10 W","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 800 A (690 V, 50 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"61.9 W","for AWG cables for auxiliary contacts":"2x (24 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"480 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/edc54ad4f5acd9fb64ac008af3feb026.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=380374&mlfb=3RT1476-2AP36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1476-2AP36/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1476-2AP36 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock count or price is published here."},{"question":"What is 3RT1476-2AP36's listed depth (225 mm) on this component line?","answer":"The depth is 225 mm, with a height of 214 mm and width of 160 mm. These dimensions include the contactor body and terminal projections."},{"question":"What is 3RT1476-2AP36's listed solid conductor range?","answer":"The spring-type terminals accept solid conductors from 0.25 to 2.5 mm², and stranded conductors up to 240 mm²."},{"question":"Will 3RT1476-2AP36 drop into a panel that was specified around 3RT1076-2AT36 without rewiring?","answer":"The 3RT1476-2AP36 is a size S12 frame; the 3RT1076-2AT36 is also an S12 frame from the same SIRIUS family. Mounting dimensions and terminal spacing are identical, so a direct mechanical swap is possible. However, verify the coil voltage — the 3RT1476-2AP36 uses 220–240 V AC/DC, while the 3RT1076 variant may differ. If coil voltage matches, no rewiring is needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1476-2AP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1476-2AP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}