{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1476-6AM36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1476-6AM36","canonicalUrl":"https://aoctrl.com/siemens/3RT1476-6AM36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AM36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, S12 contactor, 3RT1476-6AM36, 200-220 V AC/DC coil, 70-240 mm² main pole terminals, 4 auxiliary contacts, screw fixing.","salesMarkdown":"## SIRIUS S12 Contactor — 3RT1476-6AM36 Mechanical endurance is rated at 10,000,000 operations typical, with an arcing time of 10-15 ms and operating times of 60-100 ms for both AC and DC. The contactor is screw-fixed to a vertical mounting surface, rotatable ±90° and tiltable ±22.5° front-to-back. Auxiliary contact ratings are provided: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 6 A at 230 V. The auxiliary switch is present as standard. Panel integration requires screw fixing through a single 11 mm diameter hole. The contactor measures 214 mm high, 160 mm wide, and 225 mm deep. Auxiliary contact wiring accepts solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²).","metaTitle":"Siemens 3RT1476-6AM36 SIRIUS Contactor, S12, 200-220V AC/DC","metaDescription":"Siemens SIRIUS 3RT1476-6AM36 S12 contactor, 200-220V AC/DC coil, 70-240mm² main poles, 4 auxiliary contacts, screw fixing. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 220 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 ... 220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 220 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"185.7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 710 A (690 V, 100 kA)","Without Load Current Share Typical":"10 W","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 800 A (690 V, 50 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"61.9 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"480 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3fb3f5f46264b96bc779b5d58aafe653.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=75800&mlfb=3RT1476-6AM36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AM36/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"The contactor is 214 mm high, 160 mm wide, and 225 mm deep. It requires 10 mm clearance upwards, 20 mm forwards, 10 mm downwards, and 10 mm at the sides."},{"question":"What wire sizes does the main pole accept?","answer":"The main pole terminals accept stranded conductors from 70 to 240 mm²."},{"question":"What is the coil voltage and type?","answer":"The coil is rated for 200-220 V and accepts both AC and DC supply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1476-6AM36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1476-6AM36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}