{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1476-6AP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1476-6AP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1476-6AP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, size S12, order code 3RT1476-6AP36, coil 220-240 V AC/DC, screw-type terminals, 225 mm depth, current lifecycle.","salesMarkdown":"The coil is rated 220 to 240 V AC/DC, so it lands on a common control voltage for European and many Asian panels. For a conveyor or pump start/stop cycle at, say, once per minute, that is roughly 19 years of continuous service before the mechanism wears. Operate time is 60 to 100 ms on both AC and DC, so the coil pull-in is consistent regardless of supply type — no surprise delay when switching from a DC control bus. Mounting is screw fixing through a single 11 mm hole. That is tighter than many S12 contactors; you can pack it into a shallow enclosure if the ventilation is adequate. Main power path accepts stranded conductors from 70 to 240 mm² — that is the range for the load side, sized for the S12 current rating. The coil and auxiliary control wiring uses screw-type terminals accepting solid or stranded: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). That covers standard control cable sizes; no need for ferrule adapters unless the panel spec demands them.","metaTitle":"Siemens SIRIUS 3RT1476-6AP36 Contactor S12, 220-240V AC/DC","metaDescription":"Siemens SIRIUS 3RT1476-6AP36 contactor, size S12, coil 220-240 V AC/DC, 10 A at 24 V, screw fixing, 225 mm depth. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 ... 240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"185.7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 710 A (690 V, 100 kA)","Without Load Current Share Typical":"10 W","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 800 A (690 V, 50 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"61.9 W","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"480 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c9f0370c67e2f3437e4dd9c6111bb890.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=314747&mlfb=3RT1476-6AP36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AP36/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1476-6AP36?","answer":"The depth is 225 mm. That is the dimension from the mounting surface to the furthest projection, not including any add-on blocks."},{"question":"What wire sizes does the control circuit accept?","answer":"The screw-type terminals on the coil and auxiliary circuit accept solid or stranded: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²)."},{"question":"What is the coil voltage and type?","answer":"The coil is rated 220 to 240 V AC/DC, so it operates on either supply without modification."},{"question":"Does this contactor include an auxiliary switch?","answer":"Yes, an auxiliary switch is included as standard on this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1476-6AP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1476-6AP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}