{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1476-6AS36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1476-6AS36","canonicalUrl":"https://aoctrl.com/siemens/3RT1476-6AS36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AS36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, size S12, order code 3RT1476-6AS36, 225 mm depth, 160 mm width, 214 mm height, screw-type coil terminals.","salesMarkdown":"The contactor is rated for AC/DC coil voltage with a rated value of 500 to 550 V, and its auxiliary contacts handle 10 A at 24 V rated value, 2 A at 48 V, and 0.3 A at 220 V — covering typical PLC-level and relay interface loads. Mounting is via screw fixing with a vertical mounting surface, rotatable +/-90° and tiltable +/-22.5° front-to-back, giving flexibility in tight enclosures. At 225 mm depth, 160 mm width, and 214 mm height, the S12 frame fits into standard 600 mm deep enclosures with room for gland plates and wiring ducts. The main pole accepts 70 to 240 mm² stranded cable — sized for motor feeders up to the contactor's thermal rating. Auxiliary wiring uses the solid/stranded ranges listed: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², or max 2x 0.75 to 4 mm² per terminal. The coil is screw-type, so termination is straightforward with standard wire ferrules.","metaTitle":"Siemens 3RT1476-6AS36 SIRIUS Contactor, Size S12, 225 mm Dep","metaDescription":"Siemens 3RT1476-6AS36 SIRIUS contactor, size S12, rated for motor switching. Active lifecycle. Sourced to order against RFQ. Depth 225 mm, width 160 mm, height 214 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Attachable":"4","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"500 ... 550 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"500 ... 550 V","at 500 V rated value":"2 A","at 60 Hz rated value":"500 ... 550 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC in hot operating state":"185.7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 710 A (690 V, 100 kA)","Without Load Current Share Typical":"10 W","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"600 1/h","With Type Of Coordination 1 Required":"gG: 800 A (690 V, 50 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"61.9 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"480 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1a067b6077a074b09c2793621995ecfb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=43942&mlfb=3RT1476-6AS36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1476-6AS36/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel fit?","answer":"Depth is 225 mm, width is 160 mm, height is 214 mm. Clearance requirements: 10 mm downwards, 10 mm upwards, 10 mm at the side, and 20 mm forwards."},{"question":"What wire sizes does the main pole accept?","answer":"The main pole accepts stranded conductors from 70 to 240 mm². Auxiliary terminals accept solid or stranded wire: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², or max 2x 0.75 to 4 mm²."},{"question":"What are the auxiliary contact ratings?","answer":"At 24 V rated value the auxiliary contacts carry 10 A; at 48 V, 2 A; at 60 V, 2 A; at 110 V, 1 A; at 125 V, 0.9 A; at 220 V, 0.3 A; at 230 V, 6 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1476-6AS36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1476-6AS36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}