{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1517-1AD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1517-1AD00","canonicalUrl":"https://aoctrl.com/siemens/3RT1517-1AD00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1517-1AD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1517-1AD00 power contactor, Size S00, 24 VDC coil, 10 A rated current, screw terminals, 45 mm width, 72 mm depth, DIN-rail snap-on mounting.","salesMarkdown":"The Siemens 3RT1517-1AD00 is a SIRIUS-brand power contactor in the compact Size S00 frame — 45 mm wide, 57.5 mm tall, and 72 mm deep. The 24 VDC coil draws 4.4 VA at 50 Hz and pulls in with a 10 A rated current for the main contacts. Screw-type terminals on both main and auxiliary circuits accept solid or stranded wire from 0.5 mm² up to 4 mm² (AWG 20 to 12), with dual-wire entry for paralleled feeds. The 10 A rated current at 24 V DC is the continuous carry rating for the main power path — sized for small motor loads, resistive heaters, or solenoid banks within that current envelope. For DC switching at higher voltages, the ratings drop (2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V) — keep that curve in mind if you're switching DC loads above 24 V. The screw and snap-on fastening means you can pre-wire the contactor on the bench and clip it onto the rail during panel assembly. Wire range on the main contacts accepts up to 4 mm² stranded or 12 AWG solid, with dual-wire entry for looping through.","metaTitle":"Siemens 3RT1517-1AD00 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens SIRIUS 3RT1517-1AD00 power contactor, size S00, 24 VDC coil, 10 A rated. Screw terminals, DIN-rail mount. Current production. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","at AC":"4 ... 30 ms","Height":"57.5 mm","at 50 Hz":"4.4 V·A","at 60 Hz":"0.27","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Mounting Position":"with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 50 Hz rated value":"42 V","at 60 Hz rated value":"42 V","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","per NC contact rated value":"12 A","per NO contact rated value":"12 A","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at 24 V per NC contact rated value":"20 A","at 24 V per NO contact rated value":"20 A","at AC at 230 V maximum permissible":"0.003 A","reference code acc. to IEC 81346-2":"Q","at 110 V per NC contact rated value":"0.175 A","at 110 V per NO contact rated value":"0.35 A","at 220 V per NC contact rated value":"0.375 A","at 220 V per NO contact rated value":"0.75 A","at 230 V per NC contact rated value":"3 kW","at 230 V per NO contact rated value":"3 kW","at 400 V per NC contact rated value":"5.5 kW","at 400 V per NO contact rated value":"5.5 kW","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"2","number of NO contacts for main contacts":"2","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","for 3-phase AC motor at 460/480 V rated value":"5 hp","touch protection on the front acc. to IEC 60529":"finger-safe, for vertical contact from the front","protection class IP on the front acc. to IEC 60529":"IP20","Inductive Power Factor With Closing Power Of The Coil":"0.8","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor":"0.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=405678&mlfb=3RT1517-1AD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1517-1AD00/alternatives.json"},"ai":{"faq":[{"question":"What wire sizes does 3RT1517-1AD00 accept?","answer":"The screw terminals accept solid or stranded wire from 0.5 mm² to 4 mm² (AWG 20 to 12), with dual-wire entry for paralleled conductors up to 2x 4 mm²."},{"question":"Will 3RT1517-1AD00 drop into a panel designed for 3RT1017-1AD02?","answer":"Both are Size S00 contactors with the same 45 mm width and DIN-rail mounting, so the mechanical footprint and rail clip are identical. The main difference is the coil voltage and auxiliary contact configuration — verify the control circuit matches your 24 VDC supply before swapping."},{"question":"Where can I buy 3RT1517-1AD00 and how is it quoted?","answer":"This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What compliance documentation is available for 3RT1517-1AD00?","answer":"The part carries a RoHS substance prohibition compliance date of July 1, 2006, covering the standard EU directive. Additional documentation (REACH, UL, IEC) is available on request through the supply channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1517-1AD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1517-1AD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}