{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1517-2AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1517-2AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT1517-2AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1517-2AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 24 VDC coil rated 10 A, spring-loaded terminals, 45 mm width, IP20 front and terminal protection.","salesMarkdown":"## SIRIUS 3RT1517-2AP60 — Size S00 Power Contactor for 24 VDC Coil Circuits ## Coil Ratings and Switching Capacity The coil is rated for multiple control voltages: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, 3 A at 400 V, and 0.8 A at 440 V. This range covers standard industrial control voltages from low-voltage DC to 440 VAC, so the same contactor can be specified across different line voltages without changing the base part. The main circuit and auxiliary circuit both carry a rated impulse withstand voltage of 6 kV, giving adequate insulation coordination for 400 VAC panels. ## Auxiliary Contacts and Terminal Technology The main current circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded wire — no screw torque to verify, which speeds panel wiring and reduces loose-connection callbacks. The front and terminal faces carry IP20 protection, so the contactor is touch-safe in a closed enclosure but not rated for washdown environments. The mounting position allows vertical surface mounting with ±180° rotation and ±30° tilt front-to-back, so the contactor fits in tight enclosures or angled subpanels. Side-by-side mounting is permitted, which keeps the panel width compact when grouping multiple contactors.","metaTitle":"Siemens 3RT1517-2AP60 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT1517-2AP60 SIRIUS power contactor, Size S00, 24 VDC coil rated 10 A, spring-loaded terminals, IP20. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","at AC":"4 ... 30 ms","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"5.1 V·A","at 60 Hz":"0.27","Arcing time":"10 ... 15 ms","At The Side":"6 mm","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-55 ... +80 °C","Of The Terminal":"IP20","at AC-1 maximum":"1 000 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Mounting position":"with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back","Size of contactor":"S00","Product brand name":"SIRIUS","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 50 Hz rated value":"220 V","at 60 Hz rated value":"240 V","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","per NC contact rated value":"12 A","per NO contact rated value":"12 A","Of Main Circuit Rated Value":"6 kV","at maximum AC-1 rated value":"2.5 mm²","Of Auxiliary Circuit Rated Value":"6 kV","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at 24 V per NC contact rated value":"20 A","at 24 V per NO contact rated value":"20 A","at AC at 230 V maximum permissible":"0.003 A","Protection against electrical shock":"finger-safe","at 110 V per NC contact rated value":"0.175 A","at 110 V per NO contact rated value":"0.35 A","at 220 V per NC contact rated value":"0.375 A","at 220 V per NO contact rated value":"0.75 A","at 230 V per NC contact rated value":"3 kW","at 230 V per NO contact rated value":"3 kW","at 400 V per NC contact rated value":"5.5 kW","at 400 V per NO contact rated value":"5.5 kW","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"2","Number of NO contacts for main contacts":"2","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"4","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000","Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor":"0.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=75778&mlfb=3RT1517-2AP60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1517-2AP60/alternatives.json"},"ai":{"faq":[{"question":"What is the coil voltage rating for the 3RT1517-2AP60?","answer":"The coil is rated 10 A at 24 VDC, and also supports 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, 3 A at 400 V, and 0.8 A at 440 V."},{"question":"What wire sizes does the 3RT1517-2AP60 accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire per terminal."},{"question":"Where can I buy the 3RT1517-2AP60?","answer":"The 3RT1517-2AP60 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1517-2AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1517-2AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}