{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1926-2EC21","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1926-2EC21","canonicalUrl":"https://aoctrl.com/siemens/3RT1926-2EC21","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1926-2EC21","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1926-2EC21 auxiliary switch, ON-delay 0.5...10 s, coil 100...127 V AC 50/60 Hz, 3 A max contact rating, clip-on mounting.","salesMarkdown":"## What this auxiliary switch does on a 3RT1 contactor The 3RT1926-2EC21: The delay is adjustable from 0.5 to 10 seconds, set via a potentiometer on the block. Recovery time between cycles is 150 ms, which governs how quickly the delay can be re-triggered after the coil drops out. ## Contact ratings and wiring The switch contacts are rated 3 A maximum, with voltage-dependent derating: 1 A at 24 V, 0.2 A at 125 V, and 0.1 A at 250 V. These are the continuous current limits for the auxiliary circuit — typically a PLC input, a signal lamp, or a small relay coil. The block is 33 mm wide and 46 mm tall, with a depth of 73 mm when mounted on the contactor. Clip-on fastening snaps directly onto the contactor without tools. Pollution degree 3 with basic insulation — suitable for standard industrial control panels where conductive dust or humidity is present.","metaTitle":"Siemens 3RT1926-2EC21 SIRIUS Auxiliary Switch","metaDescription":"Siemens 3RT1926-2EC21 SIRIUS auxiliary switch with adjustable ON-delay 0.5-10 s. Coil 100-127 V AC. Rated 3 A max. Clip-on for 3RT1 contactors.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"18 ... 14","Width":"33 mm","title":"3RT1926-2EC21","Height":"46 mm","Maximum":"3 A","Upwards":"0 m","at 24 V":"1 A","Forwards":"0 m","ON-delay":"Yes","Stranded":"18 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","at 50 Hz":"100 ... 127 V","at 60 Hz":"100 ... 127 V","Backwards":"0 m","Downwards":"0 m","OFF delay":"No","At The Side":"0 m","description":"solid-state time-delayed front-side auxiliary switch Time range 0.5...10 s, 100... 127 V AC, 1 NO contact, 1 NC contact ON delay, for 3RT1","Non-Volatile":"No","Initial Value":"0.85","Pulse Delayed":"No","Pulse-Shaping":"No","Recovery Time":"150 ms","During Storage":"-40 ... +85 °C","Adjustable Time":"0.5 ... 10 s","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"clip-on","Full-Scale Value":"1.1","Delayed Switching":"0","Mounting Position":"any","additive ON-delay":"No","ON-delay/OFF-delay":"No","Product Brand Name":"SIRIUS","Star-Delta Circuit":"No","Type Of Insulation":"Basic insulation","Degree Of Pollution":"3","Product Designation":"auxiliary switch","at AWG cables solid":"2x (20 ... 14)","Passing Make Contact":"No","Design Of The Product":"slow-operating","Instantaneous Contact":"0","Passing Break Contact":"No","at AWG cables stranded":"2x (20 ... 14)","OFF delay/instantaneous":"No","Relative Repeat Accuracy":"1 %","Pulse Delayed/Instantaneous":"No","Pulse-Shaping/Instantaneous":"No","Substance Prohibitance (Date)":"07/01/2006","ON-delay/instantaneous contact":"No","additive ON-delay/instantaneous":"No","ON-delay/OFF-delay/instantaneous":"No","Variably Clocked With Pulse Start":"No","Control Supply Voltage Frequency 1":"50 ... 60 Hz","Relative Humidity During Operation":"15 ... 95 %","Star-Delta Circuit With Delay Time":"No","Passing Break Contact/Instantaneous":"No","Product Function Star-Delta Circuit":"No","Surge Voltage Resistance Rated Value":"4 000 V","Variably Clocked With Interval Start":"No","Constant Clock Cycle With Pulse Start":"No","EMC immunity according to IEC 61812-1":"EN 61000-6-2","Flashing Symmetrically With Pulse Start":"No","Product Component Semi-Conductor Output":"No","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","reference code according to IEC 81346-2":"K","Constant Clock Cycle With Interval Start":"No","Finely Stranded With Core End Processing":"0.5 ... 2.5 m²","Flashing Asymmetrically With Pulse Start":"No","Product Extension Optional Remote Control":"No","Product Extension Required Remote Control":"No","Flashing Symmetrically With Interval Start":"No","Passing Make Contact/Instantaneous Contact":"No","Design Of The Control Terminal Non-Floating":"No","Flashing Asymmetrically With Interval Start":"No","shock resistance according to IEC 60068-2-27":"11g / 15 ms","Retriggerable With Deactivated Control Signal":"No","Type Of Voltage Of The Control Supply Voltage":"AC","vibration resistance according to IEC 60068-2-6":"10 ... 55 Hz: 0.35 mm","Retrotriggerable With Switched-On Control Signal":"No","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","Size Of Contactor Can Be Combined Company-Specific":"S0 ... S12","electrostatic discharge according to IEC 61000-4-2":"4 kV contact discharge / 8 kV air discharge","At The Relay Outputs Switchover Delayed/Without Delay":"No","Flashing Symmetrically With Pulse Start/Instantaneous":"No","Relative Setting Accuracy Relating To Full-Scale Value":"15 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Flashing Symmetrically With Interval Start/Instantaneous":"No","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Retrotriggerable With Deactivated Control Signal/Instantaneous Contact":"No","Retrotriggerable With Switched-On Control Signal/Instantaneous Contact":"No","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$133.55","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09a8105df5c1b355776cad863f2376b5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=168855&mlfb=3RT1926-2EC21"},"ai":{"faq":[{"question":"What is the time range of the Siemens 3RT1926-2EC21?","answer":"The adjustable ON-delay range is 0.5 to 10 seconds. Recovery time between cycles is 150 ms."},{"question":"Is the 3RT1926-2EC21 compatible with my Siemens 3RT1 contactor?","answer":"Yes, this auxiliary switch block is designed to clip onto the front of a 3RT1 contactor. It adds an ON-delay function without additional wiring to the main contactor coil."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1926-2EC21","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1926-2EC21 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}