{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1926-2EC31","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1926-2EC31","canonicalUrl":"https://aoctrl.com/siemens/3RT1926-2EC31","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1926-2EC31","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary switch, 3RT1926-2EC31, ON-delay adjustable 5-100 s, coil 100-127 V AC 50/60 Hz, clip-on mounting.","salesMarkdown":"## ON-delay timer for 3RT1 contactors The 3RT1926-2EC31: This gives you a timed auxiliary contact without separate panel wiring — the delay starts when the contactor coil energises. The switch provides one delayed N/O contact rated 3 A maximum, with a 1 A rating at 24 V and 0.1 A at 250 V. The 3RT1926-2EC31 measures 33 mm wide, 46 mm high, and 73 mm deep. It clips directly onto the contactor — no DIN-rail space consumed beyond the contactor itself. Wire termination accepts solid or stranded conductors 18-14 AWG (2x 20-14 AWG for solid). The basic insulation and pollution degree 3 rating suit standard industrial control panels.","metaTitle":"Siemens 3RT1926-2EC31 SIRIUS Auxiliary Switch","metaDescription":"Siemens 3RT1926-2EC31 SIRIUS auxiliary switch with adjustable ON-delay 5-100 s, 100-127 V AC coil. Clip-on mount for 3RT1 contactors.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"18 ... 14","Width":"33 mm","title":"3RT1926-2EC31","Height":"46 mm","Maximum":"3 A","Upwards":"0 m","at 24 V":"1 A","Forwards":"0 m","ON-delay":"Yes","Stranded":"18 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","at 50 Hz":"100 ... 127 V","at 60 Hz":"100 ... 127 V","Backwards":"0 m","Downwards":"0 m","OFF delay":"No","At The Side":"0 m","description":"solid-state time-delayed front-side auxiliary switch Time range 5...100 s, 100... 127 V AC, 1 NO contact, 1 NC contact ON delay, for 3RT1","Non-Volatile":"No","Initial Value":"0.85","Pulse Delayed":"No","Pulse-Shaping":"No","Recovery Time":"150 ms","During Storage":"-40 ... +85 °C","Adjustable Time":"5 ... 100 s","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"clip-on","Full-Scale Value":"1.1","Delayed Switching":"0","Mounting Position":"any","additive ON-delay":"No","ON-delay/OFF-delay":"No","Product Brand Name":"SIRIUS","Star-Delta Circuit":"No","Type Of Insulation":"Basic insulation","Degree Of Pollution":"3","Product Designation":"auxiliary switch","at AWG cables solid":"2x (20 ... 14)","Passing Make Contact":"No","Design Of The Product":"slow-operating","Instantaneous Contact":"0","Passing Break Contact":"No","at AWG cables stranded":"2x (20 ... 14)","OFF delay/instantaneous":"No","Relative Repeat Accuracy":"1 %","Pulse Delayed/Instantaneous":"No","Pulse-Shaping/Instantaneous":"No","Substance Prohibitance (Date)":"07/01/2006","ON-delay/instantaneous contact":"No","additive ON-delay/instantaneous":"No","ON-delay/OFF-delay/instantaneous":"No","Variably Clocked With Pulse Start":"No","Control Supply Voltage Frequency 1":"50 ... 60 Hz","Relative Humidity During Operation":"15 ... 95 %","Star-Delta Circuit With Delay Time":"No","Passing Break Contact/Instantaneous":"No","Product Function Star-Delta Circuit":"No","Surge Voltage Resistance Rated Value":"4 000 V","Variably Clocked With Interval Start":"No","Constant Clock Cycle With Pulse Start":"No","EMC immunity according to IEC 61812-1":"EN 61000-6-2","Flashing Symmetrically With Pulse Start":"No","Product Component Semi-Conductor Output":"No","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","reference code according to IEC 81346-2":"K","Constant Clock Cycle With Interval Start":"No","Finely Stranded With Core End Processing":"0.5 ... 2.5 m²","Flashing Asymmetrically With Pulse Start":"No","Product Extension Optional Remote Control":"No","Product Extension Required Remote Control":"No","Flashing Symmetrically With Interval Start":"No","Passing Make Contact/Instantaneous Contact":"No","Design Of The Control Terminal Non-Floating":"No","Flashing Asymmetrically With Interval Start":"No","shock resistance according to IEC 60068-2-27":"11g / 15 ms","Retriggerable With Deactivated Control Signal":"No","Type Of Voltage Of The Control Supply Voltage":"AC","vibration resistance according to IEC 60068-2-6":"10 ... 55 Hz: 0.35 mm","Retrotriggerable With Switched-On Control Signal":"No","Mechanical Service Life (Switching Cycles) Typical":"10 000 000","Size Of Contactor Can Be Combined Company-Specific":"S0 ... S12","electrostatic discharge according to IEC 61000-4-2":"4 kV contact discharge / 8 kV air discharge","At The Relay Outputs Switchover Delayed/Without Delay":"No","Flashing Symmetrically With Pulse Start/Instantaneous":"No","Relative Setting Accuracy Relating To Full-Scale Value":"15 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Flashing Symmetrically With Interval Start/Instantaneous":"No","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Retrotriggerable With Deactivated Control Signal/Instantaneous Contact":"No","Retrotriggerable With Switched-On Control Signal/Instantaneous Contact":"No","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$40.64","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/76be4ebc0412712c8f550d117aeacecb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=309025&mlfb=3RT1926-2EC31"},"ai":{"faq":[{"question":"What is the time range of the Siemens 3RT1926-2EC31?","answer":"The adjustable ON-delay range is 5 to 100 seconds. The recovery time between cycles is 150 ms."},{"question":"Is the 3RT1926-2EC31 compatible with my 3RT1 contactor?","answer":"Yes, this auxiliary switch is designed to clip onto the front of a 3RT1 contactor. The clip-on fastening method and SIRIUS product brand confirm compatibility with the 3RT1 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1926-2EC31","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1926-2EC31 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}