{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-1AN62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-1AN62","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-1AN62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-1AN62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2015-1AN62, size S00, 24 VDC coil, screw-type terminals, 45 mm width, 73 mm depth, 58 mm height.","salesMarkdown":"The Siemens 3RT2015-1AN62 is a SIRIUS power contactor in the compact S00 frame size — 45 mm wide, 73 mm deep, 58 mm tall — designed for switching motor loads in control panels. It mounts on 35 mm DIN rail per DIN EN 60715 using the screw-and-snap-on method, with a +/-180° rotation possible on a vertical surface and +/-22.5° tilt forward/backward, giving flexibility in tight panel layouts. The coil is 24 VDC with screw-type terminals, and the auxiliary switch is integrated. Wire range accepts solid or stranded 0.5 to 4 mm², or 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm², covering common control wiring sizes. The contactor is rated for AC-3 motor switching at up to 750 cycles per hour (AC-3e also at 750/h), and AC-4 (inching/plugging) at 250 cycles per hour — so it handles frequent starts and stops within a standard production cycle. AC-1 resistive load switching is rated at 1000 cycles/h. These figures define the thermal and mechanical duty; for a motor starting once per minute, AC-3 at 750/h leaves plenty of headroom. Auxiliary contact ratings are given at various voltages: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.14 A at 440 V. These are the make/break currents for the auxiliary circuit — important for interlocking or PLC input signals. The arcing time is 10 to 15 ms at 50/60 Hz, and the switching time (at AC) is 4 to 15 ms, which is typical for this contactor class.","metaTitle":"Siemens 3RT2015-1AN62 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT2015-1AN62 SIRIUS power contactor, size S00, 24 VDC coil, screw terminals. Rated for AC-3 switching at 750 cycles/h. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.24","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"200 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.8 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$98.28","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6370bc788375072877d34cf91297db27.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3747&mlfb=3RT2015-1AN62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-1AN62/alternatives.json"},"ai":{"faq":[{"question":"What wire sizes does the 3RT2015-1AN62 accept?","answer":"Solid or stranded 0.5 to 4 mm², or 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm²."},{"question":"Will the 3RT2015-1AN62 drop into a panel specified around the 3RT2026-1AG20 without rewiring?","answer":"No — the 3RT2026-1AG20 is a size S2 contactor with different mounting dimensions and higher current rating. The 3RT2015-1AN62 is size S00, so the panel cutout, DIN rail position, and wiring may not match. A full panel review is needed."},{"question":"What compliance documentation does Siemens provide for the 3RT2015-1AN62?","answer":"The evidence does not list specific RoHS, REACH, UL, or IEC certifications for this order code. Standard Siemens SIRIUS contactors typically carry CE, UL, and CSA markings, but confirm with the manufacturer for this exact variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-1AN62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-1AN62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}