{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-1AP02-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-1AP02-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-1AP02-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-1AP02-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2015-1AP02-ZX95 power contactor, size S00, 24 VDC coil, screw-type terminals, 45 mm width, 73 mm depth, 58 mm height.","salesMarkdown":"The 3RT2015-1AP02-ZX95: It mounts via screw or snap-on onto a 35 mm DIN rail per DIN EN 60715, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward/backward — useful when you're squeezing it into a crowded panel and need to orient the coil terminals toward the wiring duct. For a machine cycling once every 10 seconds, that's roughly 8.5 years of continuous 24/7 operation before the mechanism wears out. Switching frequency depends on the duty category: 1,000 cycles/hour at AC-1 (resistive loads), 750 cycles/hour at AC-2 and AC-3 (motor starting/running), 750 at AC-3e, and 250 at AC-4 (plugging/inching). If you're running a conveyor that starts and stops every 4 seconds, you're at 900 cycles/hour — that exceeds the AC-3 limit, so you'd need to derate or step up to a larger frame. When you lay out the DIN rail, you need that 6 mm side gap to adjacent devices for proper arc extinction and heat dissipation. Wire range accepts solid or stranded from 0.5 to 4 mm², with dual-wire capability: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm². That's enough for most control-circuit wiring with standard ferrules. Auxiliary contact ratings at 24 V: 10 A; at 48 V: 2 A; at 60 V: 2 A; at 110 V: 1 A; at 125 V: 0.9 A; at 220 V: 0.3 A; at 400 V: 3 A; at 440 V: 0.14 A. Your 24 VDC power supply needs to handle the inrush peak, but the steady-state draw is under 300 mA. Operating times: AC operate 7 to 13 ms, arcing time 10 to 15 ms. That's fast enough for most motor-starting applications but not for high-speed synchronous switching where you need sub-millisecond precision. Dimensions: 45 mm wide, 73 mm deep, 58 mm high. That's the standard S00 footprint, so it drops into any panel laid out for a SIRIUS S00 contactor without re-drilling the DIN rail or re-routing the wireway.","metaTitle":"Siemens 3RT2015-1AP02-ZX95 SIRIUS Contactor, Size S00, 24 VD","metaDescription":"Siemens SIRIUS 3RT2015-1AP02-ZX95 power contactor, size S00, 24 VDC coil, screw terminals, 45 mm wide, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"7 ... 13 ms","title":"3RT2015-1AP02-ZX95","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","description":"CONTACTOR, AC-3, 3KW/400V, 1NC, AC 230V, 50/60 HZ, 3-POLE, SZ S00 SCREW TERMINAL REUSABLE PACKAGING; PACKAGE = 144 UNITS","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.2 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.4 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b9f221e862f58ffb0451fdf95fdf2834.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=411030&mlfb=3RT2015-1AP02-ZX95"},"ai":{"faq":[{"question":"What are the key dimensions of this contactor?","answer":"Width 45 mm, depth 73 mm, height 58 mm. It fits the standard S00 footprint on 35 mm DIN rail."},{"question":"What wire sizes does the 3RT2015-1AP02-ZX95 accept?","answer":"Solid or stranded wire from 0.5 to 4 mm², with dual-wire capability up to 2x 4 mm²."},{"question":"Does this contactor have an auxiliary switch built in?","answer":"Yes, it includes an auxiliary switch, so no separate side-mount block is needed for basic status feedback."},{"question":"What is the mechanical life rating?","answer":"30,000,000 operating cycles for the contactor mechanism."},{"question":"What clearance distances are required around this contactor?","answer":"10 mm upwards, forwards, and downwards; 6 mm at the side."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-1AP02-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-1AP02-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}