{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-1AV62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-1AV62","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-1AV62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-1AV62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, frame size S00, 3RT2015-1AV62, 45 mm width, screw-type coil terminals, 58 mm height, 73 mm depth, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"Screw-type coil terminals are standard; the main contact set is rated for 20–12 AWG (solid or stranded 0.5–4 mm²) and the auxiliary switch is included on the front face for status feedback or interlocking. At 58 mm height and 73 mm depth, it clears most shallow gland-plate enclosures. ## Duty Cycle and Switching Frequency Maximum switching rate depends on the load category: 1000 operations/hour in AC-1 (resistive), 750/h in AC-3 (motor start/run), and 250/h in AC-4 (plugging/inching). For AC-3e (enhanced motor switching) the same 750/h limit applies. These are the thermal limits of the contactor — exceeding them shortens mechanical life, which is rated at 30 million typical operations. ## Auxiliary Contact Ratings and Wire Range The built-in auxiliary switch handles 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V — enough for PLC input sensing or interposing relay control without an add-on block. Wire terminations accept 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or 2x 4 mm² solid or stranded, which covers most control-circuit wiring in North American and European panels. ## Environmental Range The arcing time is 10–15 ms at AC, and the magnet coil operates at 60 Hz with a 0.25 s operating time. These specs matter for cold-store or high-temp panel environments — the contactor holds its rated current across the operating band without derating.","metaTitle":"Siemens 3RT2015-1AV62 SIRIUS Power Contactor, S00 Frame, 45m","metaDescription":"Siemens SIRIUS 3RT2015-1AV62 power contactor, frame size S00, 45 mm width, screw terminals, 58 mm height, 73 mm depth. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 500 V rated value":"2 A","at 60 Hz rated value":"480 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-2 at 400 V rated value":"3 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.8 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e509102e1c29fd01c0c52093ed115233.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=391364&mlfb=3RT2015-1AV62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-1AV62/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of the 3RT2015-1AV62?","answer":"Width 45 mm, height 58 mm, depth 73 mm. It mounts on 35 mm DIN rail with 10 mm clearance upward, downward, and forward, and 6 mm to the side."},{"question":"What wire sizes does the 3RT2015-1AV62 accept?","answer":"Solid or stranded 0.5–4 mm² for the main contacts, and the auxiliary contacts accept 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or 2x 4 mm²."},{"question":"Where can I buy the 3RT2015-1AV62 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will the 3RT2015-1AV62 drop into a panel specified for the 3RT2015-1AK61?","answer":"Both are S00-frame contactors with the same 45 mm width and DIN-rail mounting, so the footprint and terminal layout are identical. The difference is the coil voltage — verify the coil rating matches your control voltage before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-1AV62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-1AV62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}