{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-2AH01-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-2AH01-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-2AH01-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-2AH01-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2015-2AH01-ZX95 power contactor, Size S00, 45 mm width, spring-type coil terminals, screw and snap-on mounting on 35 mm DIN rail (DIN EN 60715), 73 mm depth.","salesMarkdown":"## Lifecycle and Sourcing Reality The 3RT2015-2AH01-ZX95: As a current-production Siemens SIRIUS contactor, it is sourced through authorized distribution channels. Availability and current pricing are confirmed at RFQ against the BOM quantity. ## Panel Fit and Mounting Size S00 frame: 45 mm wide, 70 mm tall, 73 mm deep. The width is the critical dimension for DIN-rail density — at 45 mm it occupies one standard 45 mm module position on a 35 mm rail per DIN EN 60715. Mounting is dual-mode: screw-fixed or snap-on onto 35 mm standard mounting rail. The mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward, giving flexibility in tight enclosures. Clearance requirements: 10 mm upward, 10 mm forward, 10 mm downward, 6 mm at the side. These are the minimum air gaps for heat dissipation and arc flash clearance. ## Wiring and Terminals Main contact terminals accept solid or stranded wire: 0.5 to 4 mm² per conductor, or 2x (0.5 to 4 mm²) for paralleled feeds. The coil terminals are spring-type — push-in termination, no screw torque required. The auxiliary switch is factory-fitted (yes), so no separate add-on block is needed for basic signaling or interlocking. ## Switching Performance and Duty Cycles Rated for AC-1 (resistive) duty up to 1,000 operations per hour, AC-2 and AC-3 (motor starting) at 750 ops/h, and AC-4 (plugging/inching) at 250 ops/h. The AC-3e rating matches the AC-3 figure at 750 ops/h. Opening time (at AC) is 7 to 13 ms; arcing time is 10 to 15 ms. These timing windows are relevant for coordination with upstream protective devices and for assessing contact wear in high-cycle applications. Mechanical life of the contactor is typical 30,000,000 operations — a high-cycle rating suited for frequent switching in conveyor or pump control. ## Environmental and Storage Operating temperature range: -25 to +60 °C. Storage range: -55 to +80 °C. This covers most industrial enclosures and unheated warehouses.","metaTitle":"Siemens 3RT2015-2AH01-ZX95 SIRIUS Contactor, Size S00, 45 mm","metaDescription":"Siemens 3RT2015-2AH01-ZX95 SIRIUS power contactor, Size S00, 45 mm width, spring-type coil terminals, 35 mm DIN rail mount. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"7 ... 13 ms","title":"3RT2015-2AH01-ZX95","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","description":"power contactor, AC-3e/AC-3, 7 A, 3 kW / 400 V, 3-pole, 48 V AC, 50/60 Hz, auxiliary contacts: 1 NO, spring-loaded terminal, size: S00, reusable packaging, pack = 120 units","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"48 V","at 500 V rated value":"2 A","at 60 Hz rated value":"48 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.2 W","at AC-2 at 400 V rated value":"3 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (20 ... 12)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.2 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 12)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.4 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f1ea04419ca19aad7ab9fbaea9aca49f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=104824&mlfb=3RT2015-2AH01-ZX95"},"ai":{"faq":[{"question":"What wire sizes does the 3RT2015-2AH01-ZX95 accept?","answer":"Main contacts accept solid or stranded wire from 0.5 to 4 mm² per conductor, or 2x (0.5 to 4 mm²) for paralleled runs. Coil terminals use spring-type clamps for push-in wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-2AH01-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-2AH01-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}