{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-2AP01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-2AP01","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-2AP01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-2AP01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2015-2AP01, Size S00, 24 VDC coil, spring-type terminals, 45 mm width, 73 mm depth, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Panel Integration & Fit The 3RT2015-2AP01 is a Size S00 SIRIUS power contactor, 45 mm wide and 73 mm deep, designed for screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. This compact footprint fits standard control panel DIN-rail layouts, leaving room for adjacent motor starters or overload relays in a motor control center. Spring-type terminals on the magnet coil accept solid or stranded conductors from 0.5 to 4 mm², including 2x (0.5 to 4 mm²) for paralleled feeds. No screw torque verification needed — the spring cage provides consistent clamping force, reducing wiring time and eliminating loose-terminal callbacks during commissioning. ## Switching Performance & Duty Cycles Rated for AC-1 resistive loads at up to 1,000 operations per hour, AC-3 motor starting at 750 ops/h, and AC-4 plugging/reversing at 250 ops/h. The AC-3e rating also holds at 750 ops/h, covering energy-efficient motor applications. Arcing time runs 10 to 15 ms, with pickup and dropout at AC between 4 and 15 ms — fast enough for standard interlocking sequences. For a Tier-1 line, this supports full part genealogy — the auxiliary contact confirms the main contacts have closed, enabling zero-escape logic in the safety circuit. ## Environmental & Lifecycle The SIRIUS brand provides full compliance documentation including RoHS, REACH, and UL/IEC certifications per the product family. For automotive Tier-1 PPAP submissions, the traceable date code and batch number on the label satisfy IATF 16949 part genealogy requirements.","metaTitle":"Siemens 3RT2015-2AP01 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT2015-2AP01 SIRIUS power contactor, Size S00, 24 VDC coil, spring-type terminals, 45 mm wide, current lifecycle stage. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.2 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 12)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d34ca46a9f5d355bfeb504931b75a414.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=464857&mlfb=3RT2015-2AP01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-2AP01/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT2015-2AP01?","answer":"The depth is 73 mm, which fits standard 80 mm deep enclosures with clearance for wiring behind the DIN rail."},{"question":"Will 3RT2015-2AP01 drop into a panel specified for 3RT2015-2AP02 without rewiring?","answer":"Both are Size S00 contactors with the same 45 mm width and spring-type terminals, so the physical footprint and wiring method are identical. The difference is the coil voltage — 3RT2015-2AP01 uses 24 VDC, while 3RT2015-2AP02 uses a different coil rating. Verify the coil voltage matches your control circuit before substituting."},{"question":"What compliance documentation does Siemens provide for 3RT2015-2AP01?","answer":"As a SIRIUS product, it carries RoHS, REACH, UL, and IEC certifications standard for the series. Declarations of conformity and material declarations are available through Siemens Industry Online Support."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-2AP01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-2AP01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}