{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-2AP61-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-2AP61-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-2AP61-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-2AP61-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 3RT2015-2AP61-ZX95, 45 mm width, 73 mm depth, spring-type terminals, 24 V coil, 10 A rated switching current at 24 V.","salesMarkdown":"It measures 45 mm wide by 73 mm deep by 70 mm tall, so it tucks into a tight DIN-rail row alongside overload relays and terminal blocks. The spring-type terminals on the magnet coil accept solid or stranded wire from 0.5 to 4 mm², and the main contacts are rated for 10 A at 24 V — enough for small motors, solenoid valves, or resistive heater banks in a machine cell. Mounting is screw-and-snap onto 35 mm DIN rail per DIN EN 60715, and the contactor can be rotated ±180° on a vertical surface or tilted ±22.5° forward and backward — handy when you're shoehorning it into a crowded enclosure with awkward cable entry. The 24 V coil pulls 10 A at rated value — that's the current the contacts can make and break under resistive load at that voltage. For inductive motor duty, the AC-3 maximum operating rate is 750 cycles per hour, and the AC-4 rate drops to 250 cycles per hour for plugging or inching service. The mechanical life is a typical 30 million operations, so this contactor will outlast most of the gear it switches.","metaTitle":"Siemens 3RT2015-2AP61-ZX95 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens 3RT2015-2AP61-ZX95 SIRIUS power contactor, Size S00, 45 mm wide, spring-type terminals, 24 V coil, 10 A rated at 24 V. Current lifecycle. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.24","at 60 Hz":"0.24","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-2 at 400 V rated value":"3 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.4 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 12)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/efd593c6a23b79bdf4bdc02dd9cee17e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=385037&mlfb=3RT2015-2AP61-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-2AP61-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RT2015-2AP61-ZX95?","answer":"This contactor is sourced and quoted to order through independent industrial distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"Will 3RT2015-2AP61-ZX95 drop into a panel specified around 3RT2015-2AP01 without rewiring?","answer":"Both are Size S00 SIRIUS contactors with the same 45 mm width, 73 mm depth, and 70 mm height, so the mechanical footprint is identical. The difference is the coil termination — the -ZX95 variant uses spring-type terminals, while the -2AP01 uses screw terminals. If the panel was wired for screw terminals, you may need to change the wire-end ferrules or use a spring-to-screw adapter. Check the coil wiring before committing."},{"question":"What compliance documentation is available for this contactor?","answer":"As a Siemens SIRIUS product, it carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 standards for contactors. RoHS and REACH declarations are available from Siemens on request. Specific UL/CSA file numbers should be confirmed against the nameplate marking on the unit you receive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-2AP61-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-2AP61-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}