{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-4AG62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-4AG62","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-4AG62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-4AG62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2015-4AG62, S00 size, 24 VDC coil rated 10 A, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with a 45 mm width that fits standard panel fill patterns. The 24 VDC coil is rated for 10 A at 24 V, with the auxiliary switch integrated. ## DIN rail fit and clearances At 45 mm wide and 73 mm deep, the contactor occupies a single 45 mm DIN slot — no overhang on a standard 35 mm rail. Required clearances: 10 mm upwards, 10 mm forwards, 10 mm downwards, 6 mm at the side. The mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward, which helps when fitting into a crowded gland plate or backpanel. ## Switching capacity and operating limits Rated for 10 A at 24 VDC and 3 A at 400 VAC. The DC switching curve drops to 2 A at 48 V, 0.9 A at 125 V, and 0.3 A at 220 V — useful when specifying for DC control circuits or auxiliary loads. Maximum mechanical switching frequency: 1 000 cycles/hour at AC-1, 750 at AC-2/AC-3, 250 at AC-4. Arcing time runs 10 to 15 ms, with a 4 to 15 ms operating time at AC. Operating temperature range -25 to +60 °C; storage range -55 to +80 °C.","metaTitle":"Siemens 3RT2015-4AG62 SIRIUS Contactor, 24 VDC 10 A, S00 Siz","metaDescription":"Siemens 3RT2015-4AG62 SIRIUS power contactor, S00 size, 24 VDC coil rated 10 A. Screw and snap-on 35 mm DIN rail. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.24","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Ring cable lug connection","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Ring cable lug connection","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"ring terminal lug connection","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.8 W","At Contactor For Auxiliary Contacts":"Ring cable lug connection","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/27ec1cf864833696a09a9c3750755e30.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=63975&mlfb=3RT2015-4AG62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-4AG62/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of 3RT2015-4AG62?","answer":"Width is 45 mm, depth is 73 mm, height is 58 mm. Required clearances: 10 mm upwards, 10 mm forwards, 10 mm downwards, 6 mm at the side."},{"question":"Where can I buy 3RT2015-4AG62?","answer":"Sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time."},{"question":"Will 3RT2015-4AG62 drop into a panel specified for 3RT2015-1AV02?","answer":"Both are S00 size contactors on the same 35 mm DIN rail footprint with identical 45 mm width and 73 mm depth, so the mechanical fit is the same. The difference is the coil voltage — this unit uses a 24 VDC coil rated 10 A, while the 1AV02 variants use different coil ratings. Verify the control circuit voltage before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-4AG62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-4AG62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}