{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2015-4AK62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2015-4AK62","canonicalUrl":"https://aoctrl.com/siemens/3RT2015-4AK62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2015-4AK62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2015-4AK62 power contactor, size S00, 24 VDC coil, screw and snap-on 35 mm DIN rail mounting, 45 mm wide, 58 mm tall, 73 mm deep.","salesMarkdown":"The 45 mm width and 58 mm height fit standard S00 contactor spacing in a control panel. ## Coil and Auxiliary Contact Specifications Power consumption at both 50 and 60 Hz is 0.24 A. Its auxiliary contact ratings vary by voltage: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.14 A at 440 V, 4.8 A at 480 V, and 2 A at 500 V. For motor loads, it carries a 0.75 hp rating at 230 V. Arcing time is 4 to 15 ms at AC, with a typical arcing duration of 10 to 15 ms. ## Switching Frequency and Lifecycle Maximum switching frequency depends on duty class: 1,000 operations per hour at AC-1, 750 per hour at AC-2, AC-3, and AC-3e, and 250 per hour at AC-4. The typical mechanical service life is 30,000,000 operations. As an active-production part, the 3RT2015-4AK62 is quoted to order through Siemens distribution. The part is a direct fit for any panel designed around the S00 contactor footprint and 35 mm DIN rail.","metaTitle":"Siemens 3RT2015-4AK62 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens SIRIUS 3RT2015-4AK62 power contactor, size S00, 24 VDC coil, screw and snap-on DIN rail mount. Active production. Sourced to order. Depth 73 mm, width 45 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.24","at 60 Hz":"0.24","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Ring cable lug connection","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.14 A","at 480 V rated value":"4.8 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"120 V","at 600 V rated value":"6.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Ring cable lug connection","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"6.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"15.8 A","at AC-5b up to 400 V rated value":"5.8 A","For Auxiliary And Control Circuit":"ring terminal lug connection","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.4 W","At Contactor For Auxiliary Contacts":"Ring cable lug connection","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"120 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"67 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"52 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"43 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"2.5 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=183396&mlfb=3RT2015-4AK62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2015-4AK62/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of the 3RT2015-4AK62?","answer":"Depth is 73 mm, width is 45 mm, and height is 58 mm. Clearance requirements are 10 mm upward, forward, and downward, with 6 mm at the side."},{"question":"What is the coil voltage for this contactor?","answer":"The coil is rated for 110 V at 50 Hz and 120 V at 60 Hz, drawing 0.24 A at both frequencies. The connection type is a ring cable lug."},{"question":"What are the auxiliary contact ratings?","answer":"Auxiliary contact ratings vary by voltage: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.14 A at 440 V, 4.8 A at 480 V, and 2 A at 500 V. The motor horsepower rating is 0.75 hp at 230 V."},{"question":"What is the maximum switching frequency?","answer":"Maximum operations per hour: 1,000 at AC-1, 750 at AC-2, AC-3, and AC-3e, and 250 at AC-4. Typical mechanical service life is 30,000,000 operations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2015-4AK62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2015-4AK62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}