{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2016-1AB01-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2016-1AB01-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT2016-1AB01-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2016-1AB01-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, 3RT2016-1AB01-ZW97, size S00, 24 VDC coil, screw-type terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The Siemens 3RT2016-1AB01-ZW97 is a SIRIUS-branded power contactor in the size S00 frame, fitted with a 24 VDC magnet coil terminated to screw-type terminals. The contactor carries an integrated auxiliary switch, which simplifies wiring for status feedback or interlocking without a separate add-on block. The auxiliary contact ratings span from 10 A at 24 V rated value down to 0.2 A at 440 V rated value, covering both low-voltage PLC signals and higher-voltage indication circuits. ## Duty-cycle and switching frequency limits Maximum switching frequency depends on the duty class: AC-1 (resistive loads) allows up to 1 000 1/h, while AC-2 and AC-3 (motor starting and running) are limited to 750 1/h. The AC-3e rating also caps at 750 1/h. For AC-4 duty (plugging, inching), the rate drops to 250 1/h. These limits govern thermal rise in the coil and main contacts — exceeding them accelerates wear or causes nuisance tripping. Arcing time is specified at 10 to 15 ms at AC, with a make time of 4 to 15 ms at AC. These values matter for coordination with upstream fuses or circuit breakers — the let-through energy during a fault must be within the interrupting rating of the protective device. ## Wiring and clearance dimensions Terminals accept solid or stranded conductors from 0.5 to 4 mm², with dual-wire capability: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm². This covers common control and power wiring sizes without needing ferrule adapters. Envelope dimensions are 73 mm depth, 45 mm width, and 58 mm height. These spacings ensure adequate ventilation and arc flash containment within the panel.","metaTitle":"Siemens 3RT2016-1AB01-ZW97 SIRIUS S00 Power Contactor, 24 VD","metaDescription":"Siemens 3RT2016-1AB01-ZW97 SIRIUS S00 power contactor with 24 VDC screw-type coil, size S00 frame, snap-on DIN rail mounting. Rated for AC-3/AC-3e switching up to 750 cycles/h. Cur","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"7.6 A","at 50 Hz rated value":"24 V","at 500 V rated value":"2 A","at 60 Hz rated value":"24 V","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.33 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-2 at 400 V rated value":"4 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"155 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"111 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"66 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"55 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1e0db378c10672a2272b4741a3f2afd4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=389520&mlfb=3RT2016-1AB01-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2016-1AB01-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions and clearances for panel layout?","answer":"The contactor measures 73 mm deep, 45 mm wide, and 58 mm high. Required clearances are 10 mm upwards, forwards, and downwards, plus 6 mm at the side."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid or stranded conductors from 0.5 to 4 mm², including dual-wire combinations of 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm²."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2016-1AB01-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2016-1AB01-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}