{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2016-1AQ01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2016-1AQ01","canonicalUrl":"https://aoctrl.com/siemens/3RT2016-1AQ01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2016-1AQ01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT2016-1AQ01, screw-type coil terminals, 24 VDC coil, 10 A rated at 24 V, snap-on DIN rail mounting.","salesMarkdown":"## Siemens 3RT2016-1AQ01 — SIRIUS Power Contactor, Size S00 The main contact ratings follow the AC duty classes: AC-1 maximum 1000 switching cycles per hour, AC-2 and AC-3 at 750 cycles/h, AC-4 at 250 cycles/h. The AC-3e rating also sits at 750 cycles/h. Wire termination accepts solid or stranded conductors from 0.5 mm² up to 4 mm², with dual-wire capacity for certain combinations (2x 0.5-1.5 mm², 2x 0.75-2.5 mm², 2x 4 mm²). This covers typical control wiring sizes found in panel building. Physical dimensions: 45 mm wide, 58 mm high, 73 mm deep. The depth matters when planning enclosure depth — a standard 80 mm deep enclosure may be tight once wiring clearance is added. Ambient temperature derating may apply above 40 °C for continuous duty. The 3RT2016-1AQ01 is listed at a current lifecycle stage. The size S00 frame occupies a single 45 mm width unit on the rail. For panels with high density, maintain the 6 mm side clearance to adjacent devices for airflow and wiring access.","metaTitle":"Siemens 3RT2016-1AQ01 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT2016-1AQ01 SIRIUS power contactor, size S00, screw terminals, 24 VDC coil, rated 10 A at 24 V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"7.6 A","at 50 Hz rated value":"380 V","at 500 V rated value":"2 A","at 60 Hz rated value":"380 V","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.33 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-2 at 400 V rated value":"4 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"155 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"111 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"66 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"55 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=184941&mlfb=3RT2016-1AQ01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2016-1AQ01/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications for 3RT2016-1AQ01?","answer":"Siemens SIRIUS power contactor, size S00, 24 VDC coil, screw terminals, 10 A rated at 24 V for auxiliary contacts, wire range 0.5-4 mm² solid/stranded, 45 mm wide, 73 mm deep, operating temp -25 to +60 °C."},{"question":"Will 3RT2016-1AQ01 drop into a panel specified for 3RT2016-1AK21 without rewiring?","answer":"Both are size S00 SIRIUS contactors with identical mounting footprint (45 mm wide, snap-on DIN rail) and the same wire range (0.5-4 mm²). The difference is the coil voltage: 3RT2016-1AQ01 uses 24 VDC, while 3RT2016-1AK21 uses a different coil voltage. Verify coil voltage compatibility before substitution; no rewiring of the power or auxiliary connections is needed if the coil supply matches."},{"question":"How do I get pricing and availability for 3RT2016-1AQ01?","answer":"Submit an RFQ through the storefront. The part is sourced to order; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2016-1AQ01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2016-1AQ01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}