{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2016-2BB41-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2016-2BB41-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RT2016-2BB41-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2016-2BB41-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2016-2BB41-ZW96 power contactor, size S00, 24 VDC coil, spring-type terminals, 45 mm width, 73 mm depth, current lifecycle stage.","salesMarkdown":"## SIRIUS 3RT2016-2BB41-ZW96 — 24 VDC Coil Power Contactor, Size S00 It switches up to 10 A at 24 VDC and 3 A at 400 VAC, with a mechanical endurance typical of 30,000,000 operating cycles. The contactor mounts on a 35 mm DIN rail per DIN EN 60715, with a width of 45 mm, height of 70 mm, and depth of 73 mm — a compact footprint for panel integration. The 10 A rating at 24 VDC is the DC-1 resistive load current — the contactor handles DC loads up to that level, but for inductive DC loads (DC-13) the rating drops significantly. At 48 VDC it is rated 2 A, and at 125 VDC only 0.9 A, so for a motor brake or solenoid valve on a 24 VDC bus, the 10 A figure is the one that governs fit. The 3 A at 400 VAC covers small three-phase motor loads in AC-3 duty (squirrel-cage motors starting and disconnecting under load), with a maximum switching frequency of 750 operations per hour in AC-3. The 1 hp rating at 230 VAC confirms its use on fractional-horsepower single-phase motors. The contactor accepts solid or stranded wire from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled conductors. Spring-type terminals on the coil save wiring time — no screw torque to verify. The DC operating time (7 to 13 ms) and arcing time (10 to 15 ms) matter for coordination with upstream protection — the contactor clears faults within that window.","metaTitle":"Siemens 3RT2016-2BB41-ZW96 SIRIUS Power Contactor, 24 VDC Co","metaDescription":"Siemens SIRIUS 3RT2016-2BB41-ZW96 power contactor, size S00, 24 VDC coil, 10 A at 24 VDC. Spring-type terminals, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at DC":"7 ... 13 ms","title":"3RT2016-2BB41-ZW96","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"24 V","description":"CONTACTOR, AC-3, 4KW/400V, 1NO, DC 24V, 3-POLE, SZ S00 SPRING-LOADED TERMINAL MULTI UNIT PACKAGE PACKAGE = 60 UNITS","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"7.6 A","at 500 V rated value":"2 A","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.33 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-2 at 400 V rated value":"4 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4 W","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 12)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"DC","Limited To 1 S Switching At Zero Current Maximum":"155 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"111 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"66 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"55 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c187ba890693d2e64dc348755eaf2f43.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=36392&mlfb=3RT2016-2BB41-ZW96"},"ai":{"faq":[{"question":"What wire sizes does the 3RT2016-2BB41-ZW96 accept?","answer":"It accepts solid or stranded wire from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled conductors."},{"question":"What are the mounting dimensions and clearances?","answer":"The contactor is 45 mm wide, 70 mm high, and 73 mm deep. Required clearances: 10 mm upward, 10 mm forward, 10 mm downward, and 6 mm at the side. It mounts on a 35 mm DIN rail per DIN EN 60715."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2016-2BB41-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2016-2BB41-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}