{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2016-4AG61","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2016-4AG61","canonicalUrl":"https://aoctrl.com/siemens/3RT2016-4AG61","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2016-4AG61","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT2016-4AG61, 24 VDC coil, screw and snap-on DIN rail mount, auxiliary switch, 45 x 58 x 73 mm.","salesMarkdown":"## SIRIUS S00 power contactor — 3RT2016-4AG61 The S00 frame size keeps the footprint compact at 45 mm wide, 58 mm tall, and 73 mm deep — a space-saving fit for high-density panel layouts where every DIN rail slot counts. The auxiliary contact is rated for switching at multiple voltage levels: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.2 A at 440 V, 7.6 A at 480 V, and 2 A at 500 V. Switching frequency limits vary by duty class: 1,000 operations per hour at AC-1 (resistive loads), 750 ops/h at AC-2 and AC-3 (motor starting/running), and 250 ops/h at AC-4 (plugging/inching). For a conveyor line cycling every 5 seconds, the AC-3 limit of 750 ops/h means the contactor can handle about one start every 4.8 seconds — match your application cycle time against this ceiling. The 10 mm clearance required upwards, forwards, and downwards, plus 6 mm at the sides, dictates the minimum spacing to adjacent components in the enclosure for proper arc quenching and heat dissipation. The coil connection uses a ring cable lug — factor that into your wiring harness design if your panel standard specifies fork or pin terminals. With the S00 size and 45 mm width, this contactor occupies one standard DIN-rail module position. Plan for the 10 mm clearance above and below when laying out wire ducts and terminal blocks.","metaTitle":"Siemens 3RT2016-4AG61 SIRIUS S00 Power Contactor, 24 VDC Coi","metaDescription":"Siemens 3RT2016-4AG61 SIRIUS S00 power contactor with 24 VDC coil, auxiliary switch, screw and snap-on DIN rail mount. Active production, quoted to order. 45 mm wide, 73 mm deep.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.24","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Ring cable lug connection","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"7.6 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 V","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Ring cable lug connection","at 110/120 V rated value":"0.33 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"ring terminal lug connection","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"4.8 W","At Contactor For Auxiliary Contacts":"Ring cable lug connection","With Type Of Coordination 1 Required":"gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"155 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"111 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"86 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"66 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"55 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=101016&mlfb=3RT2016-4AG61","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2016-4AG61/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of 3RT2016-4AG61?","answer":"Width is 45 mm, height is 58 mm, and depth is 73 mm. Clearance requirements are 10 mm upwards, forwards, and downwards, and 6 mm at the sides."},{"question":"What is the auxiliary contact rating on this contactor?","answer":"The auxiliary contact is rated 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.2 A at 440 V, 7.6 A at 480 V, and 2 A at 500 V."},{"question":"Where can I buy 3RT2016-4AG61 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"Will 3RT2016-4AG61 drop into a panel specified around 3RT2015-1AV02 without rewiring?","answer":"Both are S00 frame contactors with the same DIN rail mounting and similar footprint, but the coil voltage and auxiliary contact configuration differ. Verify the coil voltage (24 VDC on this unit) and auxiliary contact ratings against your panel schematic before substituting — a deviation from the customer's approved manufacturer list requires written approval."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2016-4AG61","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2016-4AG61 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}