{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2017-1AP01-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2017-1AP01-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2017-1AP01-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2017-1AP01-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S00, 3RT2017-1AP01-ZX95, 24 VDC coil, screw-type terminals, 45 mm width, DIN rail mount.","salesMarkdown":"It carries a 24 VDC coil with screw-type terminals and includes an integrated auxiliary switch rated for 10 A at 24 V, 2 A at 48 V, and 0.3 A at 220 V — covering typical PLC and relay interface voltages without an add-on block. ## Duty-cycle limits and switching frequency The contactor's maximum switching frequency depends on the duty class: 1,000 operations per hour for AC-1 resistive loads, 750/h for AC-2 and AC-3 motor starting, and 250/h for AC-4 plugging/reversing. The AC-3e rating also caps at 750/h. These numbers define the thermal limit of the coil and main contacts — exceeding them in a high-cycle application (like a rapid-indexing conveyor) will overheat the magnet system. The practical limit will be electrical wear on the main contacts under load, not the mechanism. Main and auxiliary terminals accept solid or stranded wire from 0.5 to 4 mm², with the option of two conductors per clamp: 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or 2x 4 mm². The coil terminals are screw-type, so no special crimp tool is needed for the control wiring — a standard PZ1 or PZ2 bit handles it. The auxiliary switch is wired separately from the main poles, with its own terminal set. Arcing time is 10–15 ms at AC, and the opening time at AC is 4–15 ms — fast enough for most safety circuits but not a category-4 instant-off device. ## Environmental range and storage Storage range is wider at -55 to +80 °C — that governs shipping and warehousing, not running conditions. No end-of-life notice or last-time-buy date is on record.","metaTitle":"Siemens 3RT2017-1AP01-ZX95 SIRIUS S00 Power Contactor, 24 VD","metaDescription":"Siemens 3RT2017-1AP01-ZX95 SIRIUS power contactor, size S00, 24 VDC screw-type coil, 10 A auxiliary contacts. DIN rail mount, 45 mm wide. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"11 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.5 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"5.7 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.5 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"200 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"123 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"74 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"61 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/71546acb009f5e06461930e158deb7c2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=141857&mlfb=3RT2017-1AP01-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2017-1AP01-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT2017-1AP01-ZX95?","answer":"The listed depth is 73 mm, with a width of 45 mm and height of 58 mm — a compact S00 footprint that fits standard DIN-rail spacing."},{"question":"What wire sizes does the 3RT2017-1AP01-ZX95 accept?","answer":"Solid or stranded wire from 0.5 to 4 mm², including dual-conductor termination: 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or 2x 4 mm²."},{"question":"What compliance documentation does Siemens provide for 3RT2017-1AP01-ZX95?","answer":"As a SIRIUS catalog item, Siemens typically supplies a declaration of conformity (CE/UKCA) and material compliance declarations (RoHS, REACH) with the shipment. Specific certificates should be requested at order time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2017-1AP01-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2017-1AP01-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}