{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2017-1AP61","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2017-1AP61","canonicalUrl":"https://aoctrl.com/siemens/3RT2017-1AP61","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2017-1AP61","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2017-1AP61 power contactor, size S00, 3-pole, screw-type terminals, 45 mm width, snap-on 35 mm DIN rail mounting, 24 VDC coil.","salesMarkdown":"## S00 Frame, 45 mm Wide — Fits Tight Panels The 3RT2017-1AP61 is a SIRIUS size S00 contactor, 45 mm wide by 58 mm tall and 73 mm deep — it slides into a crowded DIN-rail section without forcing a bigger enclosure. Mounting position is forgiving: ±180° rotation on a vertical surface, plus ±22.5° tilt forward or backward. That matters when you're shoehorning contactors behind a gland plate or around a cable duct — you're not locked into one orientation. ## Switching Duty and Mechanical Life This contactor is rated for 750 operations per hour in AC-3 and AC-3e duty, 750 in AC-2, and 250 in AC-4. The mechanical life is 30 million operations typical — that's a decade-plus of daily cycling in a conveyor or pump starter before the contacts wear. The arcing time runs 10 to 15 ms, with a switching time of 4 to 15 ms at AC, so it clears fast enough to protect downstream loads without nuisance tripping. It carries a built-in auxiliary switch — one less add-on to order and wire, which keeps the BOM clean and the panel layout simpler. ## Wiring and Temperature Range Terminals accept solid wire from 0.5 to 4 mm² and stranded from 0.5 to 4 mm², plus dual-wire combinations like 2x 0.5...1.5 mm² or 2x 4 mm². The magnet coil uses screw-type terminals — no special crimp tool needed, just a standard screwdriver. Operating temperature is -25 to +60 °C, storage from -55 to +80 °C, so it handles unheated warehouses and panel summer heat without derating. ## Auxiliary Contact Ratings Across Voltages The auxiliary contacts are rated 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. That covers most control-voltage standards you'll find in a panel — 24 VDC PLC outputs, 110 VAC relay coils, or 400 VAC pilot devices. The coil power draw is 0.24 VA at both 50 Hz and 60 Hz, so the PLC output driving it doesn't see a heavy load.","metaTitle":"Siemens 3RT2017-1AP61 SIRIUS Contactor, Size S00, 45mm Wide","metaDescription":"Siemens 3RT2017-1AP61 SIRIUS power contactor, size S00, 45 mm wide, screw terminals, snap-on DIN rail mounting. Rated for 750 ops/h AC-3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.24","at 60 Hz":"0.24","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"11 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.5 W","at AC-2 at 400 V rated value":"5.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"5.9 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.5 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"200 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"123 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"74 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"61 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$136.24","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/602597e700f0e629d58b78601bc74b8d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=201450&mlfb=3RT2017-1AP61","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2017-1AP61/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the 3RT2017-1AP61?","answer":"The depth is 73 mm, with a width of 45 mm and height of 58 mm. The S00 frame size keeps the footprint compact for tight panel layouts."},{"question":"What wire sizes does the 3RT2017-1AP61 accept?","answer":"Solid wire from 0.5 to 4 mm², stranded wire from 0.5 to 4 mm², and dual-wire combinations such as 2x 0.5...1.5 mm² or 2x 4 mm². The magnet coil terminals are screw-type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2017-1AP61","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2017-1AP61 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}