{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2017-2AH02-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2017-2AH02-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RT2017-2AH02-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2017-2AH02-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2017-2AH02-ZW96 power contactor, size S00, 24 VDC coil, spring-type terminals, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"The 24 VDC coil uses spring-type terminals, so no screwdriver is needed for the coil wiring — a time-saver during panel build or swap. The contactor is rated for AC-3 duty (squirrel-cage motor switching) at up to 750 operating cycles per hour, and AC-4 (inching/plugging) at 250 cycles per hour. The AC-3e maximum is also 750 cycles/h. The main contact rating range is 20 to 12 A (likely the AC-3 current range for the S00 frame), and at 230 V it carries a 2 hp motor load. The auxiliary contact ratings span from 10 A at 24 V down to 0.2 A at 440 V — so if you're switching a 48 VDC pilot light, it handles 2 A; at 125 VDC it drops to 0.9 A. That derating curve matters when you're using the aux contacts for a PLC input or a holding circuit. Mechanical service life is typical 30 million operations, so it's built for high-cycle applications like packaging or material handling where the contactor cycles every few seconds. The contactor accepts solid or stranded wire from 0.5 to 4 mm² for the main circuit, and 2x (0.5 to 4 mm²) for paralleled conductors. The coil connection is spring-type — strip, push, done. That's tight enough for a crowded DIN rail but leave the side gap for heat dissipation. Dimensions are 45 mm wide, 70 mm high, 73 mm deep — a standard S00 footprint that fits most 35 mm DIN rail enclosures. The arcing time is 10 to 15 ms at AC, and the coil draws 0.25 A at both 50 Hz and 60 Hz.","metaTitle":"Siemens 3RT2017-2AH02-ZW96 SIRIUS Power Contactor, S00, 24 V","metaDescription":"Siemens SIRIUS 3RT2017-2AH02-ZW96 power contactor, size S00, 24 VDC coil, spring-type terminals. Rated for AC-3 switching at 750 cycles/h. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"11 A","at 50 Hz rated value":"48 V","at 500 V rated value":"2 A","at 60 Hz rated value":"48 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.5 W","at AC-2 at 400 V rated value":"5.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"5.7 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.5 W","for AWG cables for auxiliary contacts":"2x (20 ... 12)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"200 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"123 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"74 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"61 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=333108&mlfb=3RT2017-2AH02-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2017-2AH02-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this part?","answer":"As a Siemens SIRIUS product, it carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 standards for contactors. RoHS and REACH compliance documentation is typically available from Siemens. UL and CSA listings are standard for the SIRIUS line, but specific certification numbers should be verified against the nameplate or Siemens documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2017-2AH02-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2017-2AH02-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}