{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2017-2AP01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2017-2AP01","canonicalUrl":"https://aoctrl.com/siemens/3RT2017-2AP01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2017-2AP01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2017-2AP01, size S00, 24 VDC coil, spring-type terminals, 45 mm wide, 73 mm deep.","salesMarkdown":"The S00 frame keeps the footprint compact at 45 mm wide by 70 mm tall by 73 mm deep — that is a single 45 mm DIN slot, leaving room for adjacent overload relays or terminal blocks in a dense panel layout. The contactor is rated for 10 A at 24 V rated value, 3 A at 400 V rated value, and 2 hp at 230 V rated value. These are the switching capacities under the respective voltage conditions — the 10 A at 24 VDC is the figure that governs DC control-circuit loads, while the 400 V / 3 A rating covers small three-phase motor switching in AC-3 duty. That covers most indoor industrial enclosures without derating, though sustained high ambient above 60 °C would need a thermal check against the coil hold-in curve. The coil termination uses spring-type terminals accepting solid or stranded wire from 0.5 to 4 mm² (2 x 0.5 to 4 mm² for paralleled conductors). No screw torque to verify — spring clamp speeds up panel wiring and holds under vibration. That flexibility helps when the contactor sits on a swing frame or in a tight enclosure where the rail is not perfectly vertical. The 6 mm side gap is the tightest — adjacent devices need that much air space for heat dissipation and arc containment. Arcing time is 10 to 15 ms at AC, and the switching frequency ranges from 250 operations per hour at AC-4 (heavy duty) up to 1000 ops/h at AC-1 (resistive loads). If the application cycles faster than 750 ops/h in AC-3, the contactor will overheat — the AC-3e maximum is also 750 ops/h. Alternate MPNs such as 3RT2017-2AP01-ZW96, 3RT2017-2AH02-ZX95, and 3RT2017-1AB01-ZX95 carry the same S00 frame and basic ratings but differ in coil voltage or terminal type — verify the coil code before substituting in a panel specified for the -2AP01.","metaTitle":"Siemens SIRIUS 3RT2017-2AP01 Power Contactor, Size S00, 24 V","metaDescription":"Siemens SIRIUS 3RT2017-2AP01 power contactor, size S00, 45 mm wide, 73 mm deep. Spring-type coil terminals, 10 A at 24 VDC. Active production, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at AC":"4 ... 15 ms","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","at 50 Hz":"0.25","at 60 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"11 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.5 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)","Without Load Current Share Typical":"5.7 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.5 W","for AWG cables for auxiliary contacts":"2x (20 ... 12)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"200 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"123 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"74 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"61 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=63652&mlfb=3RT2017-2AP01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2017-2AP01/alternatives.json"},"ai":{"faq":[{"question":"What is the physical size of 3RT2017-2AP01?","answer":"The contactor measures 45 mm wide, 70 mm tall, and 73 mm deep. It occupies one 45 mm DIN-rail slot."},{"question":"What wire sizes does the spring terminal accept?","answer":"Solid or stranded wire from 0.5 to 4 mm² per conductor, and up to 2 x (0.5 to 4 mm²) when paralleling two conductors. No screw torque required — spring clamp termination."},{"question":"What are the clearance requirements around this contactor?","answer":"Minimum clearances: 10 mm upwards, 10 mm downwards, 10 mm forwards, and 6 mm at the side. The 6 mm side gap is the critical dimension for heat dissipation and arc containment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2017-2AP01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2017-2AP01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}