{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2018-1BB41-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2018-1BB41-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT2018-1BB41-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2018-1BB41-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2018-1BB41-ZW97 power contactor, size S00, 24 VDC coil, screw-type terminals, 45 x 58 x 73 mm, DIN rail mount.","salesMarkdown":"## S00 Frame Power Switching for Control Panels The Siemens 3RT2018-1BB41-ZW97 is a SIRIUS-brand power contactor in the compact S00 frame size, designed for switching loads in industrial control panels. It mounts on a 35 mm DIN rail per DIN EN 60715 using either screw-fastening or the integrated snap-on clip, giving the panel builder flexibility in assembly sequence. With a 24 VDC coil and screw-type terminals, this contactor handles DC switching up to 10 A at 24 V, 2 A at 48 V or 60 V, and 1 A at 110 V. The contact ratings drop to 0.3 A at 220 VDC and 3 A at 400 VAC — the DC derating curve is steep, so confirm the load current at the actual operating voltage. ## Duty-Cycle Limits and Mechanical Endurance Switching frequency depends on the duty class: 1,000 cycles per hour maximum in AC-1 (resistive loads), 750 cycles/h in AC-2 and AC-3 (motor starting/running), and 250 cycles/h in AC-4 (plugging/inching). The AC-3e rating also caps at 750 cycles/h. These limits govern the contactor's thermal recovery between operations — exceeding them accelerates contact wear. Mechanical life is typical 30 million operations, with arcing time between 7-13 ms at DC and 10-15 ms overall. The auxiliary switch is integrated, saving a separate add-on module for control-circuit feedback. ## Wiring and Panel Clearance Terminals accept solid or stranded wire from 0.5 to 4 mm², with dual-wire capacity for 2x (0.5-1.5 mm²), 2x (0.75-2.5 mm²), or 2x 4 mm². The screw-type clamp is straightforward for panel wiring but requires a screwdriver — no push-in spring cage here. Clearance requirements: 10 mm upwards and forwards, 10 mm downwards, 6 mm at the sides. The 45 x 58 x 73 mm footprint (W x H x D) fits standard S00 slot spacing. Mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward. ## Environmental Range and Lifecycle Status Operating temperature spans -25 to +60 °C, with storage from -55 to +80 °C. The coil pickup is rated at 0.8 x rated voltage (19.2 VDC for a 24 V coil) with a full-scale dropout at 1.1 x rated voltage (26.4 VDC). Lifecycle stage is listed as current production. Sourced to order against the BOM; availability and current pricing confirmed at RFQ.","metaTitle":"Siemens 3RT2018-1BB41-ZW97 SIRIUS Power Contactor, S00","metaDescription":"Siemens 3RT2018-1BB41-ZW97 SIRIUS power contactor, size S00, 24 VDC coil, screw terminals. Rated 10 A at 24 VDC. DIN rail mount. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"0.5 ... 4 mm²","Width":"45 mm","at DC":"7 ... 13 ms","title":"3RT2018-1BB41-ZW97","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"0.5 ... 4 mm²","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"24 V","description":"power contactor, AC-3e/AC-3, 16 A, 7.5 kW / 400 V, 3-pole, 24 V DC, auxiliary contacts: 1 NO, screw terminal, size: S00, multi-unit packaging, pack = 40 units","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","For Main Contacts":"20 ... 12","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.2 A","at 480 V rated value":"14 A","at 500 V rated value":"2 A","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 12","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"6.6 W","at AC-2 at 400 V rated value":"7.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"11.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"19.4 A","at AC-5b up to 400 V rated value":"13.2 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"4 W","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 50A (690V,100kA), aM: 25A (690V,100kA), BS88: 50A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"2.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RH29","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"DC","Limited To 1 S Switching At Zero Current Maximum":"300 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"169 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"128 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"92 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"74 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"4 mm²","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2a48377e0a1d92e188a1add22ea2122d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=34092&mlfb=3RT2018-1BB41-ZW97"},"ai":{"faq":[{"question":"What is the 3RT2018-1BB41-ZW97 used for?","answer":"This is a SIRIUS power contactor in the S00 frame size, used for switching motor loads and resistive loads in industrial control panels. It is rated for AC-1, AC-2, AC-3, AC-3e, and AC-4 duty classes with a 24 VDC coil and screw-type terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2018-1BB41-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2018-1BB41-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}