{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2023-2AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2023-2AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT2023-2AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2023-2AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2023-2AP60 power contactor, S0 frame size, 45 mm width, spring-type terminals, screw and snap-on mounting.","salesMarkdown":"Clearances: 10 mm upwards, downwards, and forwards; 6 mm at the sides. That 97 mm depth means it'll sit flush in a standard 120 mm deep enclosure without the gland plate hitting the back wall. The auxiliary switch terminals take 2x (0.5 to 2.5 mm²) solid or stranded. Spring-type terminals on the coil mean no screwdriver torque check — push the wire in, it's done. That's one less thing to verify during panel build-out. ## Duty cycle and switching life Rated for 1,000 switching cycles per hour at AC-1, AC-2, AC-3, and AC-3e duty; drops to 300 cycles per hour at AC-4 (the heavy inching/jogging duty). For a conveyor line running at one cycle every 3 seconds, that's about 8,300 hours of continuous operation before mechanical wear becomes a consideration. Built-in auxiliary switch rated at 10 A at 24 V, 3 A at 400 V, and 1 hp at 230 V. That 10 A at 24 V covers most PLC input modules and small relay coils without an interposing relay. If you're switching a 48 VDC indicator bank, it's good for 2 A. ## Environmental range That -25 °C low end is fine for unheated warehouses in most climates; the +60 °C top end means it'll sit next to a drive or transformer in a sealed panel without derating.","metaTitle":"Siemens 3RT2023-2AP60 SIRIUS Power Contactor, S0 Size, 45mm","metaDescription":"Siemens 3RT2023-2AP60 SIRIUS power contactor, S0 size, 45mm width, spring-type terminals, screw and snap-on DIN rail mounting, current production status.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","title":"3RT2023-2AP60","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","description":"power contactor, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, size: S0","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"7.6 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (18 ... 8)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"122 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"78 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"68 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f04e9bc5bbedd67dced0c3cecdab15d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=82280&mlfb=3RT2023-2AP60"},"ai":{"faq":[{"question":"Will the 3RT2023-2AP60 drop into a panel designed for the 3RT2024-2BB40?","answer":"Both are S0 frame size contactors with the same 45 mm width and DIN rail mounting, so the footprint and panel cutout are identical. The wiring difference is the coil termination: the 3RT2023-2AP60 uses spring-type terminals, while the 3RT2024-2BB40 uses screw terminals. No rewiring of the panel layout is needed, but the wire termination method changes."},{"question":"What is the depth of the 3RT2023-2AP60?","answer":"97 mm. That's the dimension from the DIN rail mounting surface to the front of the contactor body, not including any protruding wiring or auxiliary blocks."},{"question":"What wire sizes does the 3RT2023-2AP60 accept?","answer":"Main contacts accept 1 to 10 mm² solid or stranded. Auxiliary switch terminals accept 2x (0.5 to 2.5 mm²) solid or stranded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2023-2AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2023-2AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}