{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2023-2DB40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2023-2DB40","canonicalUrl":"https://aoctrl.com/siemens/3RT2023-2DB40","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2023-2DB40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2023-2DB40, S0 frame, 24 VDC coil, spring-type terminals, 45 mm wide, 107 mm deep.","salesMarkdown":"It carries a 24 VDC coil and uses spring-type terminals for fast wiring without screw torque checks. The contactor snaps onto a 35 mm DIN rail per DIN EN 60715 and can be rotated ±180° on a vertical surface or tilted ±22.5° forward/backward, which gives panel builders flexibility in tight enclosures. At 45 mm wide and 107 mm deep, it fits standard DIN-rail spacing and leaves room for adjacent devices. The height is 85 mm. The DC coil operates at 24 V rated value, with a pick-up/drop-out time between 15 and 17.5 ms. That 15–17.5 ms window is the mechanical response — the arcing time sits at 10 ms, so the total break time is predictable for coordination studies. The coil draws 6 A at 24 VDC inrush, settling to a lower hold current, so size your 24 VDC supply with that peak in mind. Spring-type terminals accept solid or stranded wire from 1 to 10 mm², or two conductors of 0.5 to 2.5 mm² each. That covers most control and power wiring in a typical panel — no ferrule crimping needed for solid wire, which speeds up termination on a build. Electrical switching frequency maxes out at 1,000 cycles per hour for AC-1, AC-2, AC-3, and AC-3e duty, dropping to 300 cycles per hour for AC-4 (plugging/reversing). That 300 c/h limit on AC-4 is the one that catches people out on high-cycle reversing applications.","metaTitle":"Siemens 3RT2023-2DB40 SIRIUS Power Contactor, 24 VDC Coil, S","metaDescription":"Siemens SIRIUS 3RT2023-2DB40 power contactor. 24 VDC coil, S0 frame, spring-type terminals. 45 mm wide, 107 mm deep. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"107 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at DC":"15 ... 17.5 ms","title":"3RT2023-2DB40","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","Rated Value":"24 V","description":"power contactor, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 24 V DC, with plugged-in varistor, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, size: S0","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"1 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"7.6 A","at 500 V rated value":"2 A","at 600 V rated value":"9 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.6 W","at AC-2 at 400 V rated value":"4 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"8.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2x (18 ... 8)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"7.4 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"5.9 W","closing power of magnet coil at DC":"5.9 W","holding power of magnet coil at DC":"5.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"DC","Limited To 1 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"122 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"78 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"68 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc9b4d48b3bc74db4319f90fe32ea9d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1097098&mlfb=3RT2023-2DB40"},"ai":{"faq":[{"question":"What is the closest functional alternative — 3RT2024-2BB40?","answer":"The 3RT2024-2BB40 is a higher-rated S0 frame contactor (typically 32 A vs 22 A in AC-3) with a 24 VDC coil and screw terminals instead of spring-type. It shares the same 45 mm width and 85 mm height but has a different depth and terminal layout, so a panel designed for the 3RT2023-2DB40 may need minor wiring adjustments. The spring terminals on the 3RT2023-2DB40 are the main differentiator for fast assembly."},{"question":"What is the depth of the 3RT2023-2DB40?","answer":"The depth is 107 mm, measured from the DIN rail mounting surface to the front of the contactor."},{"question":"What solid wire range does it accept?","answer":"It accepts solid conductors from 1 to 10 mm², and stranded from 1 to 10 mm² as well. It can also take two conductors of 0.5 to 2.5 mm² each."},{"question":"Will the 3RT2023-2DB40 drop into a panel designed for 3RT2024-2BB40?","answer":"Both are S0 frame size with the same 45 mm width and 85 mm height, so they share the same DIN-rail footprint and enclosure cutout. The depth differs (107 mm vs the 3RT2024-2BB40's typical 110 mm), so clearance is fine. The main difference is terminal type — spring-type on the 3RT2023-2DB40 versus screw terminals on the 3RT2024-2BB40 — so no rewiring of the panel layout is needed, but the wiring method changes."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2023-2DB40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2023-2DB40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}