{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2024-1AP00-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2024-1AP00-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RT2024-1AP00-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2024-1AP00-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2024-1AP00-ZW96, S0 frame size, 24 VDC coil, screw-type terminals, snap-on DIN rail mount.","salesMarkdown":"The 24 VDC coil with screw-type terminals is the primary control interface, and the contactor includes an integrated auxiliary switch block for feedback or interlocking circuits. The auxiliary contact ratings tell you what control voltage you can switch: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 230 V, and 3 A at 400 V. At 480 V it handles 11 A — that covers most North American control transformer secondaries. Mechanical endurance is rated at 10,000,000 operating cycles typical, with switching frequency limits of 1,000 1/h for AC-1, AC-2, AC-3, and AC-3e duty, and 300 1/h for AC-4 — the heavier the switching arc, the slower you must cycle. Wire range accepts 1 to 10 mm² solid or stranded on the main power circuit, with finer 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) for auxiliary wiring. The screw terminals are the standard captive-clamp type. The S0 frame measures 85 mm high, 45 mm wide, and 97 mm deep — a compact footprint that fits alongside other S0 devices on the same DIN rail without crowding. For buyers with an existing BOM line specifying the 3RT2024-1AP00-ZW96, the active lifecycle means no immediate replacement engineering is needed. The part is available for quotation on a per-order basis.","metaTitle":"Siemens SIRIUS 3RT2024-1AP00-ZW96 Power Contactor, S0 Size,","metaDescription":"Siemens SIRIUS 3RT2024-1AP00-ZW96 power contactor, S0 frame, 24 VDC coil, screw terminals, snap-on DIN rail mount. Current production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"11 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-2 at 400 V rated value":"5.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"12.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.6 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"126 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"105 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5bf261c0b26ee52774e1e2ffb48656c4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=143925&mlfb=3RT2024-1AP00-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2024-1AP00-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The auxiliary contacts are rated 10 A at 24 VDC, 11 A at 480 V, and 3 A at 400 V. Mechanical endurance is 10,000,000 cycles typical. Switching frequency is 1,000 1/h for AC-3 duty and 300 1/h for AC-4 duty."},{"question":"What wire sizes does this contactor accept?","answer":"Main power terminals accept 1 to 10 mm² solid or stranded. Auxiliary terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). All terminals are screw-type."},{"question":"What are the mounting dimensions and clearances?","answer":"The S0 frame is 85 mm high, 45 mm wide, 97 mm deep. Required clearances: 10 mm upwards, downwards, and forwards; 6 mm at the side. Mounts on 35 mm DIN rail per DIN EN 60715."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2024-1AP00-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2024-1AP00-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}