{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2024-1AU60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2024-1AU60","canonicalUrl":"https://aoctrl.com/siemens/3RT2024-1AU60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2024-1AU60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2024-1AU60, S0 size power contactor, 45 mm wide, screw-type coil terminals, 480 V AC-3 rated 11 A.","salesMarkdown":"It carries a 480 V AC-3 rating of 11 A, which is the real-world number you use when sizing it for a three-phase induction motor — that 11 A governs the contactor's life under full-load starts, not some resistive bench test. It mounts on a 35 mm DIN rail per EN 60715, with screw and snap-on fastening, and the mounting position is forgiving: you can rotate it ±180° on a vertical surface or tilt it ±22.5° forward and backward, which helps when you're shoehorning it into a crowded enclosure. AC-3 switching at 480 V is the headline: 11 A means this contactor handles a motor drawing about 7.5 hp at that voltage, factoring in inrush. The AC-3 duty cycle maxes out at 1,000 operations per hour, which covers most conveyor, pump, and fan applications without breaking a sweat. For the main contacts, you're looking at AWG 16 to 8 roughly, which is standard for this frame class. That -25 °C low end means it's fine for unheated plant spaces in most climates, but if you're in a deep-freeze warehouse, you'll want to verify the coil pick-up at the actual ambient.","metaTitle":"Siemens SIRIUS 3RT2024-1AU60 Power Contactor, S0 Size, 480V","metaDescription":"Siemens SIRIUS 3RT2024-1AU60 power contactor, S0 frame, 45mm wide, screw terminals, 480V AC-3 rated 11A, current production. DIN rail mount. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"11 A","at 500 V rated value":"2 A","at 60 Hz rated value":"277 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.5 W","at AC-2 at 400 V rated value":"5.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"12.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (16 ... 12), 2x (14 ... 8)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.5 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"162 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"103 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"88 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=913197&mlfb=3RT2024-1AU60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2024-1AU60/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the 3RT2024-1AU60?","answer":"It is an S0-frame contactor rated 11 A at 480 V AC-3 for motor switching. It accepts wire from 1 to 10 mm² solid or stranded, operates from -25 to +60 °C, and mounts on a 35 mm DIN rail."},{"question":"Will the 3RT2024-1AU60 drop into a panel specified for a 3RT2025-1AD20-1AA0?","answer":"Both are S0-frame Siemens contactors, so the physical footprint and DIN rail mounting are the same. The difference will be in the coil voltage and auxiliary contact configuration — check those against your panel wiring before assuming a direct swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2024-1AU60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2024-1AU60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}