{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2024-2AK60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2024-2AK60","canonicalUrl":"https://aoctrl.com/siemens/3RT2024-2AK60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2024-2AK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2024-2AK60 power contactor, S0 frame, 24 VDC spring-type coil, size S0, 45 mm width, 97 mm depth, 102 mm height.","salesMarkdown":"It mounts on 35 mm DIN rail per DIN EN 60715, with screw and snap-on fastening, and can be rotated ±180° on a vertical surface or tilted ±22.5° forward/backward, giving you flexibility in tight enclosures. The coil uses spring-type terminals, rated 24 VDC, and the auxiliary contacts are rated 10 A at 24 V, 2 hp at 230 V, and 3 A at 400 V — solid for signaling back to a PLC or driving a pilot light. ## Integration Notes Wire the main contacts with solid or stranded copper from 1 to 10 mm²; auxiliary contacts accept 2x (0.5 to 2.5 mm²). The spring-type coil terminals are tool-less — just push in the stripped wire. Clearance around the contactor: 10 mm above and below, 6 mm to the side. The arcing time is 10 ms, so keep that in mind for coordination with upstream protection. ## Duty Ratings Rated for 1 000 operations per hour in AC-1, AC-2, AC-3, and AC-3e duty; AC-4 drops to 300 operations per hour.","metaTitle":"Siemens 3RT2024-2AK60 SIRIUS Power Contactor, S0 Frame, 24 V","metaDescription":"Siemens SIRIUS 3RT2024-2AK60 power contactor, S0 frame, 24 VDC spring-type coil. Rated for 2 hp at 230 V and 3 A at 400 V on auxiliary contacts. Quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"11 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"120 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"12.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"126 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"105 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$22.86","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/caee715707e952d1571f75c99460903d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=251413&mlfb=3RT2024-2AK60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2024-2AK60/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RT2024-2AK60 and how is it quoted for volume purchases?","answer":"It is sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is 3RT2024-2AK60's depth?","answer":"The depth is 97 mm, with a width of 45 mm and height of 102 mm."},{"question":"What wire sizes does 3RT2024-2AK60 accept?","answer":"The main contacts accept solid or stranded wire from 1 to 10 mm²; auxiliary contacts accept 2x (0.5 to 2.5 mm²) solid or stranded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2024-2AK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2024-2AK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}