{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2024-4AN60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2024-4AN60","canonicalUrl":"https://aoctrl.com/siemens/3RT2024-4AN60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2024-4AN60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2024-4AN60, S0 frame, 45 mm width, 97 mm depth, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"The Siemens 3RT2024-4AN60 is a SIRIUS power contactor in the S0 frame size, built for screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. It occupies 45 mm width on the rail and reaches 97 mm deep into the enclosure — a tight fit for a contactor with an integrated auxiliary switch, so plan gland-plate clearance accordingly. Width is 45 mm, depth 97 mm, height 85 mm. Clearance requirements: 10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side. The mounting position allows ±180° rotation on a vertical surface and ±22.5° forward/backward tilt — useful when fitting into a crowded backplate where the rail orientation isn't standard. ## Ratings and operating conditions Rated for AC-1, AC-2, AC-3, and AC-3e duty at up to 1,000 operations per hour; AC-4 maxes out at 300 1/h. Operating temperature range is -25 to +60 °C, with storage from -55 to +80 °C. The magnet coil connection uses a ring cable lug — factor that into your control wiring prep.","metaTitle":"Siemens 3RT2024-4AN60 SIRIUS Power Contactor, S0 Frame, 45 m","metaDescription":"Siemens 3RT2024-4AN60 SIRIUS power contactor, S0 frame, 45 mm width, 97 mm depth. Screw and snap-on DIN rail mounting. Current lifecycle stage. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Width":"45 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Ring cable lug connection","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"2 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"11 A","at 50 Hz rated value":"200 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 V","at 600 V rated value":"11 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Ring cable lug connection","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"0.9 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"12.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"9.9 A","For Auxiliary And Control Circuit":"ring terminal lug connection","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.9 W","At Contactor For Auxiliary Contacts":"Ring cable lug connection","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.3 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"126 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"105 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fa4469760c046d051c3668dc3b2841ea.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=108913&mlfb=3RT2024-4AN60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2024-4AN60/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT2024-4AN60?","answer":"Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is 3RT2024-4AN60's listed depth on this component line?","answer":"97 mm depth, with 45 mm width and 85 mm height. Clearance needs are 10 mm upwards, forwards, and downwards, plus 6 mm at the side."},{"question":"Will 3RT2024-4AN60 drop into a panel specified around 3RT2015-4AP62 without rewiring?","answer":"Both are S0 frame contactors with the same DIN rail mounting footprint, so the mechanical swap is straightforward. Verify your control voltage and auxiliary contact configuration against the existing wiring before the swap — the coil connection type and auxiliary arrangement may differ."},{"question":"What compliance documentation does this brand provide for 3RT2024-4AN60?","answer":"As a Siemens SIRIUS product, standard compliance documentation including RoHS, REACH, UL, and IEC declarations are available through the manufacturer's documentation portal or upon request with the order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2024-4AN60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2024-4AN60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}