{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2025-2EL20","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2025-2EL20","canonicalUrl":"https://aoctrl.com/siemens/3RT2025-2EL20","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2025-2EL20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S0, order code 3RT2025-2EL20, spring-type terminals, 45 mm width, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"It mounts via screw or snap-on onto 35 mm standard mounting rail per DIN EN 60715, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward and backward — useful when you're fitting into a tight enclosure layout. The main contacts are rated 18 A for AC-3 duty (motor switching) at 400 V, and 8 A for AC-1 (resistive load) at the same voltage. That 18 A AC-3 rating means it handles a 7.5 kW motor at 400 V three-phase — the typical sizing for a small conveyor or pump. The auxiliary switch is rated 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 0.6 A at 440 V — these are the contact ratings for the built-in auxiliary block, so you can use it for PLC feedback or status indication without adding a separate aux contactor. Switching frequency maxes out at 1,000 operating cycles per hour for AC-1, AC-2, AC-3, and AC-3e duty, dropping to 300 cycles per hour for AC-4 (plugging/inching). Spring-type terminals on the magnet coil and main/auxiliary contacts accept solid or stranded wire from 1 to 10 mm², with dual-wire capacity for 2x (0.5 to 2.5 mm²). The 45 mm width and 97 mm depth fit the standard S0 footprint — same as the 3RT2015 and 3RT2016 siblings, so it drops into the same DIN rail slot without re-drilling the panel. ## Environmental and mounting notes","metaTitle":"Siemens 3RT2025-2EL20 SIRIUS Power Contactor, Size S0, Sprin","metaDescription":"Siemens 3RT2025-2EL20 SIRIUS power contactor, Size S0, 45 mm wide, spring-type terminals, screw and snap-on DIN rail mount. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"3 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"14 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"17 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"15 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.8 W","at AC-2 at 400 V rated value":"7.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"15.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with RC elements","at AWG cables for main contacts":"2x (18 ... 8)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"14.1 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"7.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.6 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"225 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"225 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"180 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"115 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=568976&mlfb=3RT2025-2EL20","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2025-2EL20/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2025-2EL20 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"Will 3RT2025-2EL20 drop into a panel specified around 3RT2015-2AP01?","answer":"Yes — both are Size S0 contactors with the same 45 mm width and DIN rail mounting footprint, so the mechanical fit is identical. The difference is in the coil voltage and auxiliary contact configuration; verify those match your control circuit before ordering."},{"question":"What is the depth of 3RT2025-2EL20?","answer":"The depth is 97 mm, with a width of 45 mm and height of 102 mm."},{"question":"What wire sizes does the spring terminal accept?","answer":"Solid or stranded wire from 1 to 10 mm², and dual-wire capacity for 2x (0.5 to 2.5 mm²)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2025-2EL20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2025-2EL20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}