{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2025-2NP30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2025-2NP30","canonicalUrl":"https://aoctrl.com/siemens/3RT2025-2NP30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2025-2NP30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, S0 size, 3RT2025-2NP30, 200-280 VAC coil, spring-type terminals, 45 mm width, screw and snap-on mounting on 35 mm DIN rail (DIN EN 60715).","salesMarkdown":"The contactor is rated for switching loads at up to 1,000 operating cycles per hour under AC-1, AC-2, AC-3, and AC-3e duty, with a reduced 300 cycles/hour for AC-4 (high-inrush or plugging duty). Inrush current peaks at 25 A, which the coil supply must handle without voltage sag. Arcing time is a tight 10 ms, which keeps arc energy contained within the contactor housing. Wire termination uses spring-type terminals on the coil, accepting solid or stranded conductors from 1 to 10 mm², with double-wire capability at 2x (0.5 to 2.5 mm²). The main contact arrangement is 3-pole normally open (3RT series standard), with an auxiliary switch block included as standard. Coil pickup is rated at 0.7 x nominal voltage, dropout at 0.51 x nominal at 50 Hz (0.56 at 60 Hz). Switching times for both AC and DC coils are 30 to 50 ms.","metaTitle":"Siemens 3RT2025-2NP30 SIRIUS Power Contactor, S0, 200-280VAC","metaDescription":"Siemens 3RT2025-2NP30 SIRIUS power contactor, S0 frame, 200-280VAC coil, spring-type terminals, 45mm wide, DIN rail mount. Current lifecycle stage, available to order. Quoted on re","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"107 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"30 ... 50 ms","at DC":"30 ... 50 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.51","at 60 Hz":"0.56","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","Rated Value":"200 ... 280 V","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"25 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"3 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"14 A","at 50 Hz rated value":"200 ... 280 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 280 V","at 600 V rated value":"17 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"15 hp","Locked-Rotor Current Peak":"0.13 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"17 mA","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"1.8 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"15.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"30 µs","Locked-Rotor Current Mean Value":"0.1 A","at AWG cables for main contacts":"2x (18 ... 8)","Duration Of Locked-Rotor Current":"180 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"14.1 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)","Without Load Current Share Typical":"4.3 W","closing power of magnet coil at DC":"14.3 W","holding power of magnet coil at DC":"1.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)","at AWG cables for auxiliary contacts":"2x (20 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"0.6 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"225 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"225 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"180 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"115 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"96 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5aaee030cc403a5e902cfa288608a583.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=235995&mlfb=3RT2025-2NP30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2025-2NP30/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RT2025-2NP30 and how is it quoted for volume purchases?","answer":"This part is supplied through independent industrial-automation distribution channels. Volume pricing and lead time are quoted against an RFQ — no firm price or stock count is published here."},{"question":"Will 3RT2025-2NP30 drop into a panel specified around 3RT2015-2AP02 without rewiring?","answer":"Both are S0-frame SIRIUS contactors with the same 45 mm width and DIN-rail mounting pattern, so the mechanical footprint is identical. The main difference is the coil voltage: 3RT2025-2NP30 uses a 200-280 VAC coil, while the 3RT2015-2AP02 uses a different coil rating. Verify coil supply before swapping — the terminals and wiring space are the same spring-type design."},{"question":"What is 3RT2025-2NP30's listed depth?","answer":"The depth is 107 mm, with a width of 45 mm and height of 102 mm. This fits standard S0 contactor panel layouts."},{"question":"What compliance documentation does Siemens provide for 3RT2025-2NP30?","answer":"As a SIRIUS product, the 3RT2025-2NP30 carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 for contactors. RoHS and REACH declarations are available from Siemens documentation. No UL or CSA listing is confirmed in the available spec data."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2025-2NP30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2025-2NP30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}