{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2026-1AK60-0UA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2026-1AK60-0UA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2026-1AK60-0UA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2026-1AK60-0UA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2026-1AK60-0UA0 power contactor, size S0, 45 mm width, screw-type coil terminals, 3 hp at 230 V, auxiliary contacts, current production.","salesMarkdown":"Rated for 3 hp at 230 V, it handles typical induction motors in that power class. The auxiliary contacts are rated 10 A at 24 V, 2 A at 48 V, and 0.9 A at 125 V — enough for pilot duty or PLC feedback in most line-voltage schemes. The AC-3 switching rate of 750 operations per hour tells you this contactor is designed for motor starting under load — typical for conveyors, pumps, and compressors. If your application requires frequent reversing, watch that AC-4 ceiling. Wire range accepts solid or stranded 1 to 10 mm², and fine-stranded 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). That covers most motor and control wiring in a standard panel. The screw-type coil terminals are straightforward to terminate — no special tooling needed. Clearances: 10 mm upwards, downwards, and forwards; 6 mm at the sides. That's tight enough for dense panel layouts — just keep the side gap for heat dissipation.","metaTitle":"Siemens SIRIUS 3RT2026-1AK60-0UA0 Power Contactor, Size S0,","metaDescription":"Siemens SIRIUS 3RT2026-1AK60-0UA0 power contactor, size S0, 45 mm width, screw terminals, 3 hp at 230 V, 10 A auxiliary contacts, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","title":"3RT2026-1AK60-0UA0","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","description":"CONTACTOR, 10HP 460/575V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"3 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"21 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"120 V","at 600 V rated value":"22 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"2 hp","at 200/208 V rated value":"7.5 hp","at 220/230 V rated value":"7.5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"10 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"5.7 W","at AC-2 at 400 V rated value":"11 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"15.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"20.7 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)","Without Load Current Share Typical":"10.5 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"1.9 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"375 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"300 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"210 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"144 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"118 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$40.64","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c95f70e73aa1e1c4e62264e1d3b581d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=376591&mlfb=3RT2026-1AK60-0UA0"},"ai":{"faq":[{"question":"What is the closest functional second-source — the 3RT2026-1AG20?","answer":"The 3RT2026-1AG20 is a peer in the same SIRIUS size S0 family, but the 3RT2026-1AK60-0UA0 includes an auxiliary switch and screw-type coil terminals. The 1AG20 variant may differ in coil voltage or auxiliary configuration — verify the coil rating and auxiliary contact count before substituting."},{"question":"What are the key dimensions for panel layout?","answer":"Width is 45 mm, height 85 mm, depth 97 mm. Clearances: 10 mm upwards, downwards, and forwards; 6 mm at the sides."},{"question":"What wire sizes does it accept?","answer":"Solid or stranded 1 to 10 mm². Fine-stranded: 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). Main contacts accept 16 to 8 AWG."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2026-1AK60-0UA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2026-1AK60-0UA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}