{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2026-2NP30-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2026-2NP30-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2026-2NP30-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2026-2NP30-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2026-2NP30-ZX95 power contactor, size S0, 200-280 V AC coil, spring-type terminals, 45 mm width, 102 mm height, 107 mm depth.","salesMarkdown":"The 45 mm width and 102 mm height match the S0 footprint, with a depth of 107 mm. ## Duty Ratings and Switching Cycles This contactor is rated for different utilization categories: AC-1 at 1,000 operating cycles per hour, AC-2 and AC-3 at 750 cycles per hour, and AC-4 at 250 cycles per hour. The AC-3 rating covers standard squirrel-cage motor switching — the most common motor load in industrial panels. The AC-4 rating, for reversing or inching duty, is lower at 250 cycles per hour, reflecting the increased electrical wear from making and breaking stalled rotor current. The auxiliary switch is included, which simplifies ordering for applications needing status feedback. ## Coil and Auxiliary Contact Ratings The coil draws an inrush peak of 25 A and holds at a lower sealed current. Operating times are 30-50 ms on AC and 30-45 ms on DC. The auxiliary contacts are rated at 10 A at 24 V, 2 A at 48 V and 60 V, and 1 A at 110 V. These ratings determine the signal-level switching capability for PLC inputs or indicator lamps in the control circuit. ## Environmental and Mechanical Life The mechanical life is typically 10,000,000 operations. Conductor sizes accepted: solid or stranded 1-10 mm² for main contacts, and 2x (0.5-2.5 mm²) for auxiliary contacts.","metaTitle":"Siemens 3RT2026-2NP30-ZX95 SIRIUS Power Contactor, S0, 200-2","metaDescription":"Siemens SIRIUS 3RT2026-2NP30-ZX95 power contactor, size S0, 200-280 V AC coil, spring-type terminals. Current lifecycle. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"107 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"30 ... 50 ms","at DC":"30 ... 45 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.51","at 60 Hz":"0.56","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","Rated Value":"200 ... 280 V","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"25 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"3 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"21 A","at 50 Hz rated value":"200 ... 280 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 280 V","at 600 V rated value":"22 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"2 hp","at 200/208 V rated value":"5 hp","at 220/230 V rated value":"7.5 hp","at 460/480 V rated value":"15 hp","at 575/600 V rated value":"20 hp","Locked-Rotor Current Peak":"0.13 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"17 mA","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"4.8 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"15.5 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"30 µs","Locked-Rotor Current Mean Value":"0.1 A","at AWG cables for main contacts":"2x (18 ... 8)","Duration Of Locked-Rotor Current":"180 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"35.2 A","at AC-5b up to 400 V rated value":"20.7 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)","Without Load Current Share Typical":"4.3 W","closing power of magnet coil at DC":"14.3 W","holding power of magnet coil at DC":"1.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"1.6 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"375 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"299 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"200 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"128 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"106 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4afd25e4c9a2acb98c48ba8fd36c032.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=296594&mlfb=3RT2026-2NP30-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2026-2NP30-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2026-2NP30-ZX95 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote."},{"question":"What is the closest functional second-source for 3RT2026-2NP30-ZX95?","answer":"The 3RT2015-2AP02 is a smaller frame size (S00 vs S0) with a different coil voltage (230 V AC) and screw terminals instead of spring-type. It will not drop into the same panel without rewiring due to the different footprint and terminal style."},{"question":"What are the key dimensions of 3RT2026-2NP30-ZX95?","answer":"Width is 45 mm, height 102 mm, and depth 107 mm. Clearance requirements are 10 mm upwards, forwards, and downwards, and 6 mm at the sides."},{"question":"What conductor sizes does the 3RT2026-2NP30-ZX95 accept?","answer":"Main contacts accept solid or stranded conductors from 1 to 10 mm². Auxiliary contacts accept 2x (0.5 to 2.5 mm²) solid or stranded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2026-2NP30-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2026-2NP30-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}