{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2027-1AL24-3MA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2027-1AL24-3MA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2027-1AL24-3MA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2027-1AL24-3MA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, S0 power contactor, 3RT2027-1AL24-3MA0, 24 VDC coil, screw-type terminals, 45 mm width, DIN rail snap-on mounting.","salesMarkdown":"At 45 mm wide, it fits the S0 frame slot without crowding adjacent devices. The AC-3 switching frequency of 750 operations per hour tells you this contactor handles motor start-stop cycles at a solid production pace — think conveyor sections or pump stations that cycle every few seconds. The AC-1 resistive rating at 1000 ops/h covers heater banks or lighting contactor duty. Mechanical life is typical at 10 million operations, so it outlasts most panel refreshes. The 24 VDC coil draws 6 A at rated voltage; verify your control transformer can support that inrush across multiple contactors pulling simultaneously. That puts it in the range for small three-phase motors — 2.2 kW at 400 V or a 3.7 kW at 230 V, roughly. The screw-type main terminals accept solid or stranded wire from 1 to 10 mm², which covers standard motor feeds up to 4 mm² for a 2.2 kW drive. ## Panel integration and mounting flexibility That matters when you're squeezing this into a tight gland-plate layout or a swing-frame panel.","metaTitle":"Siemens 3RT2027-1AL24-3MA0 SIRIUS S0 Power Contactor, 24 VDC","metaDescription":"Siemens SIRIUS 3RT2027-1AL24-3MA0 S0 power contactor, 24 VDC coil, screw terminals, 45 mm wide, DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"141 mm","Solid":"1 ... 10 mm²","Width":"45 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"No","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"5 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"27 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"27 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"2 hp","at 200/208 V rated value":"10 hp","at 220/230 V rated value":"10 hp","at 460/480 V rated value":"20 hp","at 575/600 V rated value":"25 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"6.3 W","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"22 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"44 A","at AC-5b up to 400 V rated value":"26.5 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)","Without Load Current Share Typical":"10.5 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"2.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"499 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"341 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"260 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"199 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"162 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=456248&mlfb=3RT2027-1AL24-3MA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2027-1AL24-3MA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3RT2027-1AL24-3MA0?","answer":"Submit an RFQ through this listing. We source and quote to order; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source to 3RT2027-1AL24-3MA0?","answer":"The 3RT2026-1BB40-0UA0 is a peer in the same S0 frame, but it uses a different coil voltage (not 24 VDC) and has different auxiliary contact configuration. Verify coil compatibility before substituting — the mechanical footprint and DIN rail mounting are shared, but the coil draw and terminal arrangement differ."},{"question":"Will 3RT2027-1AL24-3MA0 drop into a panel wired for 3RT2026-1BB40-0UA0?","answer":"The S0 frame size and DIN rail mounting are identical, so the mechanical fit is the same. However, check the coil voltage — the 3RT2027-1AL24-3MA0 uses 24 VDC, while the 3RT2026-1BB40-0UA0 may use a different coil rating. Also verify auxiliary contact wiring if the existing panel uses a different aux configuration."},{"question":"What compliance documentation is available for this contactor?","answer":"As a standard Siemens SIRIUS product, it carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 for contactors. RoHS and REACH declarations are available from Siemens documentation. UL/CSA listings are typical for this series but verify the specific file number for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2027-1AL24-3MA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2027-1AL24-3MA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}