{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2028-4AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2028-4AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT2028-4AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2028-4AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS Size S0 power contactor, 3RT2028-4AP60, 34 A at 480 V, 45 mm wide, screw and snap-on DIN rail mount, auxiliary switch included.","salesMarkdown":"## SIRIUS Size S0 Power Contactor — 3RT2028-4AP60 An integrated auxiliary switch provides feedback for status indication or interlocking without needing a separate add-on block. ## Ratings and Switching Performance Rated for 34 A at 480 V, 60 Hz — this is the AC-3 motor switching current, meaning it handles the locked-rotor inrush during starting and the running current under load. Switching frequency: up to 1 000 operations per hour at AC-1 resistive loads, 750/h at AC-2 and AC-3 motor loads, and 250/h at AC-4 (plugging/inching) — the AC-4 limit is the one that governs heavy-duty jogging applications. Arcing time is 10...10 ms — a tight window that helps with contactor life and coordination with upstream protection. Coil connection uses a ring cable lug — ensure your control wiring terminates with the correct ring terminal size for reliable connection. Auxiliary contact ratings: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V, 2 A at 500 V — the 24 V rating is what most PLC outputs will drive; the higher-voltage ratings drop off significantly, so size your pilot circuits accordingly. Operating temperature range is -25 to +60 °C during operation, with storage from -55 to +80 °C — the operating limit is the one that matters for enclosure ambient; if your panel hits 60 °C internally, you're at the edge.","metaTitle":"Siemens 3RT2028-4AP60 SIRIUS Power Contactor, Size S0, 34 A","metaDescription":"Siemens SIRIUS 3RT2028-4AP60 power contactor, Size S0, 34 A at 480 V, 45 mm wide, screw and snap-on DIN rail mount, auxiliary switch included. Current lifecycle. Sourced to order a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Width":"45 mm","at AC":"4 ... 16 ms","title":"3RT2028-4AP60","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","description":"power contactor, AC-3e/AC-3, 38 A, 18.5 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, ring cable lug connection, size: S0","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Ring cable lug connection","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"5 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"34 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"27 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"Ring cable lug connection","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"10 hp","at 220/230 V rated value":"10 hp","at 460/480 V rated value":"25 hp","at 575/600 V rated value":"25 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"9.6 W","at AC-2 at 400 V rated value":"18.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"22 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"44 A","at AC-5b up to 400 V rated value":"31.5 A","For Auxiliary And Control Circuit":"ring terminal lug connection","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)","Without Load Current Share Typical":"10.5 W","At Contactor For Auxiliary Contacts":"Ring cable lug connection","With Type Of Coordination 1 Required":"gG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3.2 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"593 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"341 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"260 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"199 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"162 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/54dc7c0a81950d5c5d7ac0e5fc0f64e3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=376236&mlfb=3RT2028-4AP60"},"ai":{"faq":[{"question":"What are the key dimensions of 3RT2028-4AP60?","answer":"It measures 85 mm high, 45 mm wide, and 97 mm deep, with clearance requirements of 10 mm upwards, forwards, and downwards, and 6 mm at the side."},{"question":"Does 3RT2028-4AP60 include an auxiliary switch?","answer":"Yes, it comes with an integrated auxiliary switch, providing feedback for status indication or interlocking without a separate add-on block."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2028-4AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2028-4AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}