{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2035-3AG60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2035-3AG60","canonicalUrl":"https://aoctrl.com/siemens/3RT2035-3AG60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2035-3AG60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, Power contactor, 3RT2035-3AG60, size S2, 480 V rated value 40 A, spring-type terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"It carries a 480 V rated value of 40 A, which tells you the continuous current it can handle at that voltage level — useful for sizing against a motor nameplate or resistive load bank. That 55 mm width and 114 mm height, 130 mm depth footprint fits standard panel layouts — just watch the side clearance if you're packing multiple contactors side-by-side. ## Switching performance and thermal limits Rated for 1 200 operations per hour at AC-1 (resistive), 1 000 at AC-3 (motor start/run), and 300 at AC-4 (plugging/inching). The arcing time runs 10 to 20 ms, and the closing time at AC is 10 to 18 ms. The mechanical life of the contactor typical is 10 000 000 operations — that's the mechanical endurance, not the electrical life under load, which depends on your switching duty and current.","metaTitle":"Siemens 3RT2035-3AG60 SIRIUS Power Contactor, 480V 40A, Spri","metaDescription":"Siemens SIRIUS 3RT2035-3AG60 power contactor, size S2, 480V rated 40A, spring-type terminals, screw and snap-on DIN rail mount. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Width":"55 mm","at AC":"10 ... 18 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.36","at 60 Hz":"0.39","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"7.5 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"40 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"100 ... 110 V","at 600 V rated value":"41 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"10 hp","at 220/230 V rated value":"15 hp","at 460/480 V rated value":"30 hp","at 575/600 V rated value":"40 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"6.6 W","at AC-2 at 400 V rated value":"18.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"35 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"52.8 A","at AC-5b up to 400 V rated value":"33.2 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)","Without Load Current Share Typical":"18.5 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"2.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"843 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"596 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"400 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"241 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"196 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6bc8cab26d2b41519789dd59917cf393.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=148025&mlfb=3RT2035-3AG60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2035-3AG60/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Size S2, 480 V rated at 40 A, spring-type coil terminals, screw and snap-on DIN rail mount, operating range -25 to +60 °C."},{"question":"What clearance is needed around the contactor?","answer":"10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2035-3AG60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2035-3AG60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}