{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2035-3AR60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2035-3AR60","canonicalUrl":"https://aoctrl.com/siemens/3RT2035-3AR60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2035-3AR60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S2 power contactor, 3RT2035-3AR60, 480 V AC-3 rated 40 A, 7.5 hp at 230 V, spring-type coil terminals, screw and snap-on 35 mm DIN rail mount.","salesMarkdown":"It carries a 480 V AC-3 rating of 40 A — that's the motor-switching current for a pump, fan, or conveyor drive at that voltage — and a 7.5 hp rating at 230 V for smaller North American motor circuits. The S2 frame is the mid-size in the SIRIUS contactor family, balancing panel space (55 mm wide, 114 mm tall, 130 mm deep) against the contact gap needed for 480 V interruption. Mounts on 35 mm DIN rail per EN 60715 via screw or snap-on fastening, and the mounting position allows ±180° rotation on a vertical surface plus ±22.5° tilt forward/backward — useful when the panel layout forces an unconventional orientation. The coil connection uses spring-type terminals, so no screwdriver needed on the coil side; main and auxiliary contacts use screw terminals. ## Duty-cycle and switching frequency limits The contactor's switching frequency depends on the duty class. For AC-1 resistive loads you can cycle it up to 1 200 operations per hour. AC-3 motor switching (starting and running disconnect) allows 1 000 ops/h. The more punishing AC-4 duty — plugging or inching the motor — drops to 300 ops/h. These aren't theoretical ceilings; exceed them and the contact gap temperature rises past the arc-chamber's recovery rate, which accelerates contact erosion. The arcing time sits between 10 and 20 ms, and the magnet coil dropout is 10 to 18 ms at AC. ## Environmental range and auxiliary switching The auxiliary switch block is included (18 to 1 contact configuration for the main contacts), which gives you one N/O or N/C auxiliary for status feedback or interlocking without adding a separate block. The auxiliary contacts carry 10 A at 24 V, derating to 0.3 A at 220 V and 0.6 A at 440 V — enough for PLC inputs or small relay coils at control voltage, but check the volt-amp curve if you're switching a larger contactor's coil through the auxiliary.","metaTitle":"Siemens 3RT2035-3AR60 SIRIUS S2 Power Contactor, 480 V 40 A","metaDescription":"Siemens 3RT2035-3AR60 SIRIUS S2 power contactor. 480 V AC-3 rated 40 A, 7.5 hp at 230 V. Spring-type coil terminals, DIN rail mount. Current production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Width":"55 mm","at AC":"10 ... 18 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.36","at 60 Hz":"0.39","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"7.5 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"40 A","at 50 Hz rated value":"400 V","at 500 V rated value":"2 A","at 60 Hz rated value":"400 ... 440 V","at 600 V rated value":"41 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"10 hp","at 220/230 V rated value":"15 hp","at 460/480 V rated value":"30 hp","at 575/600 V rated value":"40 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"6.6 W","at AC-2 at 400 V rated value":"18.5 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"35 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"52.8 A","at AC-5b up to 400 V rated value":"33.2 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)","Without Load Current Share Typical":"18.5 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"2.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"843 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"596 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"400 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"241 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"196 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc4e5f3c13d008e7b8834052f5ae360a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1089870&mlfb=3RT2035-3AR60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2035-3AR60/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2035-3AR60 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What are the key dimensions of 3RT2035-3AR60?","answer":"Width 55 mm, height 114 mm, depth 130 mm. The S2 frame fits standard 35 mm DIN rail with screw or snap-on mounting."},{"question":"What is the AC-3 motor rating at 480 V for 3RT2035-3AR60?","answer":"Rated 40 A at 480 V in AC-3 duty, and 7.5 hp at 230 V. That covers typical 15–25 hp three-phase motors at 480 V depending on the motor full-load current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2035-3AR60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2035-3AR60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}