{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2036-1AL24-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2036-1AL24-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2036-1AL24-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2036-1AL24-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, order code 3RT2036-1AL24-ZX95, 55 mm width, 52 A at 480 V AC-3, 230 V 50 Hz coil, screw terminals.","salesMarkdown":"## What you're looking at It's rated to switch motor loads at 52 A continuous in AC-3 duty at 480 V — that's the number that matters for picking the right motor starter. The coil pulls 230 V at 50 Hz and draws 0.36 A holding current (0.39 A at 60 Hz). Screw-type terminals on the coil and main contacts, so no special tooling needed for a panel rebuild. ## Panel fit and clearances This contactor measures 55 mm wide by 114 mm tall by 174 mm deep. You need 10 mm clearance above, below, and in front, and only 6 mm on the sides, so it packs tight in a crowded enclosure. ## Ratings for the real route The AC-3 rating at 52 A and 480 V is what governs motor switching. For lighter duty, AC-1 resistive loads can cycle up to 1 000 operations per hour, while AC-4 (plugging/inching) tops out at 250 per hour.","metaTitle":"Siemens 3RT2036-1AL24-ZX95 SIRIUS Power Contactor, 55 mm, 52","metaDescription":"Siemens SIRIUS 3RT2036-1AL24-ZX95 power contactor, size S2, 55 mm wide, 52 A at 480 V AC-3. Screw terminals, 230 V 50 Hz coil. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"174 mm","Width":"55 mm","at AC":"10 ... 18 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.36","at 60 Hz":"0.39","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"No","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"800 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"52 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"52 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"15 hp","at 220/230 V rated value":"15 hp","at 460/480 V rated value":"40 hp","at 575/600 V rated value":"50 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"12 W","at AC-2 at 400 V rated value":"22 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"41 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"61.6 A","at AC-5b up to 400 V rated value":"41.5 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)","Without Load Current Share Typical":"17.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"4 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"937 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"697 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"468 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"282 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"229 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"25 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ca006971dbf4c28fa43b8f2d83f3f24.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=241245&mlfb=3RT2036-1AL24-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2036-1AL24-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RT2036-1AL24-ZX95 and how is it quoted for volume purchases?","answer":"This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is 3RT2036-1AL24-ZX95's listed depth?","answer":"The depth is 174 mm."},{"question":"What is 3RT2036-1AL24-ZX95's listed width?","answer":"The width is 55 mm."},{"question":"What compliance documentation does this brand provide for 3RT2036-1AL24-ZX95?","answer":"As a Siemens SIRIUS product, it carries standard industrial approvals including IEC and UL certifications. Specific RoHS, REACH, and UL documentation is available through the manufacturer's support channels."},{"question":"Where can I buy 3RT2036-1AL24-ZX95?","answer":"It is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2036-1AL24-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2036-1AL24-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}